Physiological basis for BOLD MR signal changes due to neuronal stimulation: Separation of blood volume and magnetic susceptibility effects

被引:87
作者
Kennan, RP
Scanley, BE
Innis, RB
Gore, JC
机构
[1] Yale Univ, Sch Med, Dept Diagnost Radiol, New Haven, CT 06520 USA
[2] W Haven Vet Affairs Med Ctr, Dept Psychiat, W Haven, CT USA
关键词
fMRI; blood volume; susceptibility;
D O I
10.1002/mrm.1910400609
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An NMR method is applied for separating blood volume and magnetic susceptibility effects in response to neuronal stimulation in a rat model. The method uses high susceptibility contrast agents to enhance blood volume induced signal changes. In the absence of erogenous agent; the dominant source of signal change on neuronal activation is associated with the signal increase from the blood oxygen level dependent (BOLD) effect The relative negative contribution of blood volume changes to BOLD changes is maximally estimated to be 34%. The blood volume changes associated with median nerve stimulation (7 Hz) in the motor colter are 26 +/- 7% and the corresponding blood susceptibility changes are 0.021 +/- 0.006 ppm. These methods can be applied to enhance the sensitivity of fMRI signal response and provide accurate quantitative measures of blood volume response to stimulation.
引用
收藏
页码:840 / 846
页数:7
相关论文
共 36 条
[11]   MEASUREMENT OF REGIONAL BLOOD OXYGENATION AND CEREBRAL HEMODYNAMICS [J].
HOPPEL, BE ;
WEISSKOFF, RM ;
THULBORN, KR ;
MOORE, JB ;
KWONG, KK ;
ROSEN, BR .
MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (06) :715-723
[12]   Evaluation of the early response in fMRI in individual subjects using short stimulus duration [J].
Hu, XP ;
Le, TH ;
Ugurbil, K .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :877-884
[13]   DYNAMIC MAGNETIC-RESONANCE-IMAGING OF THE RAT-BRAIN DURING FOREPAW STIMULATION [J].
HYDER, F ;
BEHAR, KL ;
MARTIN, MA ;
BLAMIRE, AM ;
SHULMAN, RG .
JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1994, 14 (04) :649-655
[14]   INTRAVASCULAR SUSCEPTIBILITY CONTRAST MECHANISMS IN TISSUES [J].
KENNAN, RP ;
ZHONG, JH ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 31 (01) :9-21
[15]   Physiologic basis for BOLD MR signal changes due to hypoxia/hyperoxia: Separation of blood volume and magnetic susceptibility effects [J].
Kennan, RP ;
Scanley, BE ;
Gore, JC .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (06) :953-956
[16]   Perfusion imaging by a flow-sensitive alternating inversion recovery (FAIR) technique: Application to functional brain imaging [J].
Kim, SG ;
Tsekos, NV .
MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) :425-435
[17]  
LAI S, 1996, P ISMRM 4 ANN M NEW, P1756
[18]   SIMULTANEOUS MEASUREMENTS OF MICROFLOW AND EVOKED-POTENTIALS IN THE SOMATOMOTOR CORTEX OF THE CAT BRAIN DURING SPECIFIC SENSORY ACTIVATION [J].
LENIGERFOLLERT, E ;
HOSSMANN, KA .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1979, 380 (01) :85-89
[19]   CHARACTERIZATION OF CBF RESPONSE TO SOMATOSENSORY STIMULATION - MODEL AND INFLUENCE OF ANESTHETICS [J].
LINDAUER, U ;
VILLRINGER, A ;
DIRNAGL, U .
AMERICAN JOURNAL OF PHYSIOLOGY, 1993, 264 (04) :H1223-H1228
[20]   Dynamic functional imaging of relative cerebral blood volume during rat forepaw stimulation [J].
Mandeville, JB ;
Marota, JJA ;
Kosofsky, BE ;
Keltner, JR ;
Weissleder, R ;
Rosen, BR ;
Weisskoff, RM .
MAGNETIC RESONANCE IN MEDICINE, 1998, 39 (04) :615-624