Chip-based refractive index detection using a single point evanescent wave probe

被引:16
作者
Jakeway, SC [1 ]
de Mello, AJ [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, AstraZeneca SmithKline Beecham Ctr Analyt Sci, Dept Chem, London SW7 2AY, England
关键词
D O I
10.1039/b104350c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a novel approach for performing spectroscopic refractive index detection within microfluidic channel environments. Based on the principle of total internal reflection (TIR), changes in the refractive index of an analyte stream passing through a microfabricated channel are detected through interaction with an optical evanescent field formed at the channel wall. Refractive index variations within the microchannel environment modify the critical angle at the liquid-solid inter-face, thereby altering the characteristics of evanescent field formation in solution. These variations are evidenced through measurement of fluorescence intensities. Initially, the design and testing of the method are described, Subsequently, refractive index values for bulk sucrose solutions (0-35% w/v sucrose in water) are measured using the single point evanescent wave probe and compared with values obtained through conventional refractometry and the literature. Close agreement between all three approaches is demonstrated. The method is then applied to the detection of sucrose plugs (10-500 mM) hydrodynamically flowing through microfabricated channels on a planar glass chip. The evanescent wave probe is also used to selectively monitor specific analytes within a multicomponent system, by precise angular control in the vicinity of the critical angle. Although detection limits using the prototype system are non-ideal (similar to 5 muM carbohydrate), they compare favourably with existing methods for on-chip refractive index detection.
引用
收藏
页码:1505 / 1510
页数:6
相关论文
共 32 条
[1]   Sub-microliter electrochemiluminescence detector - A model for small volume analysis systems [J].
Arora, A ;
de Mello, AJ ;
Manz, A .
ANALYTICAL COMMUNICATIONS, 1997, 34 (12) :393-395
[2]  
Atkins P.W., 1983, MOL QUANTUM MECH
[3]   DETECTING SINGLE MOLECULES IN LIQUIDS [J].
BARNES, MD ;
WHITTEN, WB ;
RAMSEY, JM .
ANALYTICAL CHEMISTRY, 1995, 67 (13) :A418-A423
[4]   Holographic refractive index detector for application in microchip-based separation systems [J].
Burggraf, N ;
Krattiger, B ;
de Mello, AJ ;
de Rooij, NF ;
Manz, A .
ANALYST, 1998, 123 (07) :1443-1447
[5]   Variable-angle time-resolved evanescent wave-induced fluorescence spectroscopy (VATR-EWIFS): A technique for concentration profiling fluorophores at dielectric interfaces [J].
Byrne, CD ;
de Mello, AJ ;
Barnes, WL .
JOURNAL OF PHYSICAL CHEMISTRY B, 1998, 102 (50) :10326-10333
[6]  
Chen DR, 1998, CHEM J CHINESE U, V19, P1
[7]   EVANESCENT-WAVE SPECTROSCOPIC STUDIES OF SURFACE-ENHANCED FLUORESCENCE QUANTUM EFFICIENCIES [J].
DEMELLO, AJ ;
CRYSTALL, B ;
RUMBLES, G .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 1995, 169 (01) :161-167
[8]   Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips [J].
Effenhauser, CS ;
Bruin, GJM ;
Paulus, A ;
Ehrat, M .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3451-3457
[9]  
EIJKEL JCT, 1999, ORGANIC MESOSCOPIC C, P185
[10]  
Haab BB, 1998, BIOPHYS J, V74, pA9