Design equations for evaluating fire resistance of SFRC-filled HSS columns

被引:42
作者
Kodur, VKR [1 ]
机构
[1] Natl Res Council Canada, Inst Res Construct, Ottawa, ON K1A 0R6, Canada
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1998年 / 124卷 / 06期
关键词
D O I
10.1061/(ASCE)0733-9445(1998)124:6(671)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Computer programs were developed and used to investigate the influence of various factors on the fire resistance of steel hollow structural section columns filled with steel fiber-reinforced concrete. Results from the parametric studies were used to develop simple equations for calculating the fire resistance of steel fiber-reinforced concrete (SFRC)-filled hollow structural section (HSS) columns with circular and square cross sections. The validity of the calculation procedure was established by comparing the calculated fire resistances with those obtained from fire tests on columns. These equations provide a rational and easy-to-use design method for evaluating the fire resistance of hollow steel columns filled with steel fiber-reinforced concrete for any value of the significant parameters that determine it, such as load, cross-sectional dimensions, effective length, and concrete strength. The proposed equations give reasonable estimate of fire resistance for SFRC-filled circular HSS columns; however, the predicted fire resistances can be overconservative for SFRC-filled square HSS columns. Hence, these equations can be used in preliminary design and, where available, the designer should rely on furnace testing when not satisfied with the estimated fire resistance values.
引用
收藏
页码:671 / 677
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 1992, 78 ASCE
[2]  
[Anonymous], 1989, CANULCS101
[3]  
[Anonymous], 1990, E11988 ASTM
[4]  
[Anonymous], CANCSAS161M89
[5]  
[Anonymous], 1995, NAT BUILD COD CAN
[6]  
CHABOT M, 1992, 628 IRC NAT RES COUN
[7]  
GRANDJEAN G, 1991, HDB STEEL CONSTRUCTI
[8]  
Grandjean G., 1981, DETERMINATION DUREE
[9]  
Kodur V. K. R, 1996, 590 IRC NAT RES COUN
[10]   Fire resistance or circular steel columns filled with fiber-reinforced concrete [J].
Kodur, VKR ;
Lie, TT .
JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (07) :776-782