Percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas

被引:80
作者
Demharter, J
Müller, P
Wagner, T
Schlimok, G
Haude, K
Bohndorf, K
机构
[1] ZentralKlinikum Augsburg, Dept Radiol, D-86156 Augsburg, Germany
[2] ZentralKlinikum Augsburg, Dept Internal Med, Med Clin 2, D-86156 Augsburg, Germany
[3] ZentralKlinikum Augsburg, Dept Pathol, D-86156 Augsburg, Germany
[4] ZentralKlinikum Augsburg, Dept Anesthesiol & Intens Care Med, D-86156 Augsburg, Germany
关键词
lymphoma; needle biopsy; interventional US; X-ray CT scanners;
D O I
10.1007/s003300000540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The objective of this study was to evaluate the sensitivity and specificity of percutaneous core-needle biopsy of enlarged lymph nodes in the diagnosis and subclassification of malignant lymphomas. In a 1-year period 158 image-guided percutaneous core-needle biopsies of enlarged lymph nodes were performed on 149 consecutive patients using a Tru-cut needle fired by a biopsy gun. In 135 cases the biopsy findings could be confirmed by histologic examination of additional tissue samples (n = 59) or by correlation with the patient's clinical and radiologic course (n = 76). The final diagnoses were malignant lymphoma in 65 cases, leukemic nodal infiltration in 2, nodal metastases from a solid tumor in 37 and benign changes or no evidence of malignancy in 31 cases. The core-needle biopsies correctly diagnosed 58 of 65 malignant lymphomas, corresponding to a sensitivity of 89 % and a specificity of 97 %, Fifty-five of the 58 (95 %) correctly diagnosed malignant lymphomas could be subclassified on the basis of the core-needle biopsy. Image-guided core-needle biopsy of enlarged lymph nodes with a Tru-cut needle is a useful method for the diagnosis and subclassification of malignant lymphomas.
引用
收藏
页码:276 / 283
页数:8
相关论文
共 31 条
  • [1] Image-guided core-needle biopsy in malignant lymphoma: Experience with 100 patients that suggests the technique is reliable
    BenYehuda, D
    Polliack, A
    Okon, E
    Sherman, Y
    Fields, S
    Lebenshart, P
    Lotan, H
    Libson, E
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 1996, 14 (09) : 2431 - 2434
  • [2] ULTRASONICALLY GUIDED FINE-NEEDLE BIOPSY - A NEW USEFUL TECHNIQUE IN PATHOLOGICAL STAGING OF MALIGNANT-LYMPHOMA
    BUSCARINI, L
    CAVANNA, L
    FORNARI, F
    ROSSI, S
    BUSCARINI, E
    [J]. ACTA HAEMATOLOGICA, 1985, 73 (03) : 150 - 152
  • [3] CAFFERTY LL, 1990, CANCER, V65, P72, DOI 10.1002/1097-0142(19900101)65:1<72::AID-CNCR2820650116>3.0.CO
  • [4] 2-Q
  • [5] CARRASCO CH, 1990, RADIOL CLIN N AM, V28, P879
  • [6] Dawson-Saunders B., 1994, Basic and clinical biostatistics, V2
  • [7] MEDIASTINOSCOPY VS ANTERIOR MEDIASTINOTOMY IN THE DIAGNOSIS OF MEDIASTINAL LYMPHOMA - A RANDOMIZED TRIAL
    ELIA, S
    CECERE, C
    GIAMPAGLIA, F
    FERRANTE, G
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 1992, 6 (07) : 361 - 365
  • [8] ERWIN BC, 1986, CANCER, V57, P1074, DOI 10.1002/1097-0142(19860301)57:5<1074::AID-CNCR2820570535>3.0.CO
  • [9] 2-E
  • [10] CT-GUIDED CUTTING-NEEDLE BIOPSIES OF SELECTED CHEST LESIONS
    GORALNIK, CH
    OCONNELL, DM
    ELYOUSEF, SJ
    HAAGA, JR
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1988, 151 (05) : 903 - 907