High-performance liquid chromatographic determination of stabilized 4-hydroxyifosfamide in human plasma and erythrocytes

被引:21
作者
Kerbusch, T
Huitema, ADR
Kettenes-van den Bosch, JJ
Keizer, HJ
Ouwerkerk, J
de Kraker, J
Beijnen, JH
机构
[1] Slotervaart Hosp, Netherlands Canc Inst, Dept Pharm & Pharmacol, NL-1066 EC Amsterdam, Netherlands
[2] Univ Utrecht, Fac Pharm, NL-3508 TG Utrecht, Netherlands
[3] Leiden Univ Hosp, Dept Clin Oncol, NL-2333 AA Leiden, Netherlands
[4] Univ Amsterdam, Acad Med Ctr, Dept Pediat Oncol, NL-1105 AZ Amsterdam, Netherlands
来源
JOURNAL OF CHROMATOGRAPHY B | 1998年 / 716卷 / 1-2期
关键词
4-hydroxyifosfamide;
D O I
10.1016/S0378-4347(98)00298-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method using reversed-phase high-performance liquid chromatography (RP-HPLC) is described for the measurement of the stabilized activated metabolite of ifosfamide, 4-hydroxyifosfamide (4-OHIF), in human plasma and erythrocytes. Immediately after sample collection and plasma-erythrocyte separation at 4 degrees C, 4-OHIF was stabilized by derivatization with semicarbazide (SCZ). The sample pretreatment involved liquid-liquid extraction with ethyl acetate. RP-HPLC was executed with a C-8 column and acetonitrile-0.025 M potassium dihydrogenphosphate buffer (pH 7.40)-triethylamine (13.5:86:0.5, v/v) as mobile phase. The analyte was determined with UV detection at 230 nm. Complete validation, optimisation and stability studies were performed and the method proved to be specific, sensitive and with a stable analyte in the range of clinically relevant concentrations (0.1-10 mu g/ml) after conventional dosing. The lower limit of quantitation was 100 ng/ml using 1.00 ml of sample. Accuracy was between 94.1 and 107.0%. Within-day and between-day precisions were less than 6.2% and 7.2%, respectively. 4-OHIF-SCZ was found to be stable in the biological matrix at -20 degrees C for at least 1 month. A pharmacokinetic study conducted in a patient receiving 9 g/m(2) over 3 days by means of a continuous infusion, demonstrated the applicability of this method. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:275 / 284
页数:10
相关论文
共 10 条
[1]   MEASUREMENT OF 4-HYDROXYCYCLOPHOSPHAMIDE IN SERUM BY REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
BELFAYOL, L ;
GUILLEVIN, L ;
LOUCHAHI, K ;
LORTHOLARY, O ;
BOSIO, AM ;
FAUVELLE, F .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02) :395-399
[2]   COMBINED THIN-LAYER CHROMATOGRAPHY PHOTOGRAPHY DENSITOMETRY FOR THE QUANTIFICATION OF IFOSFAMIDE AND ITS PRINCIPAL METABOLITES IN URINE, CEREBROSPINAL-FLUID AND PLASMA [J].
BODDY, AV ;
IDLE, JR .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 575 (01) :137-142
[3]   Nuclear magnetic resonance and high-performance liquid chromatography nuclear magnetic resonance studies on the toxicity and metabolism of ifosfamide [J].
Foxall, PJD ;
Lenz, EM ;
Lindon, JC ;
Neild, GH ;
Wilson, ID ;
Nicholson, JK .
THERAPEUTIC DRUG MONITORING, 1996, 18 (04) :498-505
[4]   Activated oxazaphosphorines are transported predominantly by erythrocytes [J].
Highley, MS ;
Schrijvers, D ;
Van Oosterom, AT ;
Harper, PG ;
Momerency, G ;
Van Cauwenberghe, K ;
Maes, RAA ;
De Bruijn, EA ;
Edelstein, MB .
ANNALS OF ONCOLOGY, 1997, 8 (11) :1139-1144
[5]  
Highley MS, 1996, INT J CANCER, V65, P711
[6]  
IKEUCHI I, 1985, CHEM PHARM BULL, V33, P2416
[7]   Determination of 4-hydroxyifosfamide in biological matrices by high-performance liquid chromatography [J].
Kaijser, GP ;
TerRiet, PGJH ;
deKraker, J ;
Bult, A ;
Beijnen, JH ;
Underberg, WJM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1997, 15 (06) :773-781
[8]   GAS-CHROMATOGRAPHIC DETERMINATION OF IFOSFAMIDE IN MICROVOLUMES OF URINE AND PLASMA [J].
KAIJSER, GP ;
BEIJNEN, JH ;
BULT, A ;
WIESE, G ;
DEKRAKER, J ;
UNDERBERG, WJM .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 571 (1-2) :121-131
[9]  
MARTINO R, 1992, J PHARMACOL EXP THER, V260, P1133
[10]   Analysis of ifosfamide, 4-hydroxyifosfamide, N2-dechloroethylifosfamide, N3-dechloroethylifosfamide and iphosphoramide mustard in plasma by gas chromatography mass spectrometry [J].
Wang, JJH ;
Chan, KK .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 674 (02) :205-217