Direct power control of PWM converter without power-source voltage sensors

被引:658
作者
Noguchi, T [1 ]
Tomiki, H [1 ]
Kondo, S [1 ]
Takahashi, I [1 ]
机构
[1] Nagaoka Univ Technol, Dept Elect & Elect Syst Engn, Nagaoka, Niigata 9402188, Japan
关键词
direct power control; hysteresis comparator; instantaneous active power; instantaneous reactive power; pulsewidth modulation converter; switching table; total power factor; voltage sensorless operation;
D O I
10.1109/28.673716
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper proposes a novel control strategy of a pulewidth modulation (PWM) converter with no power-source voltage sensors. The strategy has two main features to improve a total power factor and efficiency, taking harmonic components into account without detecting the voltage waveforms, One feature is a direct instantaneous power control technique for the converter, which has been developed to control the instantaneous active and reactive power directly by selecting the optimum switching state of the converter. The other feature is an estimation technique of the power-source voltages, which can be performed by calculating the active and reactive power for each switching state of the converter from the line currents. A digital-signal-processor-based experimental system was developed, and experimental tests were conducted to examine the controllability. As a result, it was confirmed that the total power factor and efficiency were more than 97% and 93% over the load power range from 200 to 1400 W, respectively. These results have proven the excellent performance of the proposed system.
引用
收藏
页码:473 / 479
页数:7