Personalized image-based templates for precise acetabular prosthesis placement in total hip arthroplasty: a pilot study

被引:10
作者
Chen, Bin [1 ]
Xiao, Sheng-xiang [1 ]
Gu, Peng-cheng [1 ]
Lin, Xiang-jin [1 ]
机构
[1] Zhejiang Univ, Sch Med, Affiliated Hosp 1, Dept Orthopaed, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Total hip arthroplasty; Templates; Acetabular prosthesis; COMPONENT ORIENTATION; POLYETHYLENE WEAR; DISLOCATION; DYSPLASIA;
D O I
10.1631/jzus.B1000066
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
070307 [化学生物学]; 071010 [生物化学与分子生物学];
摘要
In order to achieve accurate implantation of the acetabular prosthesis in total hip arthroplasty (THA), we designed individual templates based on a three-dimensional (3D) model generated from computed tomography (CT) scans. Individual templates were designed for 12 patients who underwent THA. A physical template was designed to conform to the contours of the patient's acetabulum and to confirm the rotation of the acetabular center. This guided the acetabular component orientation. The preoperative and postoperative X-ray and CT scans were obtained to assess the location with respect to the accuracy of the acetabular component. For all patients, the abduction angle of the acetabular component was 46.7A degrees to 54.3A degrees and the anteversion angle was 11.3A degrees to 18.5A degrees. The assessment of postoperative CT scans demonstrated higher accuracy of the acetabular component bore when used with the individual template. Therefore, the individual template can be an alternative to the computer-assisted navigation systems, with a good cost-performance ratio.
引用
收藏
页码:673 / 680
页数:8
相关论文
共 23 条
[1]
Rapid prototyping: The future of trauma surgery? [J].
Brown, GA ;
Firoozbakhsh, K ;
DeCoster, TA ;
Reyna, JR ;
Moneim, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A :49-55
[2]
Definition and determination of acetabular component orientation in cemented total hip arthroplasty [J].
Cross, AR ;
Newell, SM .
VETERINARY SURGERY, 2000, 29 (06) :507-516
[3]
The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios [J].
D'Lima, DD ;
Urquhart, AG ;
Buehler, KO ;
Walker, RH ;
Colwell, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) :315-321
[4]
Reliable acetabular cup orientation with a new gravity-assisted guidance system [J].
Echeverri, S ;
Leyvraz, PF ;
Zambelli, PY ;
Jolles, BM .
JOURNAL OF ARTHROPLASTY, 2006, 21 (03) :413-419
[5]
Evaluation of the Hip Center in Total Hip Arthroplasty for Old Developmental Dysplasia [J].
Flecher, Xavier ;
Parratte, Sebastien ;
Brassart, Nicolas ;
Aubaniac, Jean-Manuel ;
Argenson, Jean-Noel .
JOURNAL OF ARTHROPLASTY, 2008, 23 (08) :1189-1196
[6]
Galantucci L. M., 2006, Journal of Medical Engineering & Technology, V30, P102, DOI 10.1080/03091900500131714
[7]
Acetabular component orientation in intra- and postoperative positions in total hip arthroplasty [J].
Hayakawa, Keiko ;
Minoda, Yukihide ;
Aihara, Masaharu ;
Sakawa, Akira ;
Ohzono, Kenji ;
Tada, Koichi .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (09) :1151-1156
[8]
ICHMANN T, 1997, ACTA ORTHOP SCAND S, V276, P1
[9]
Wear of polyethylene acetabular components in total hip arthroplasty - An analysis of one hundred and twenty-eight components retrieved at autopsy or revision operations [J].
Jasty, M ;
Goetz, DD ;
Bragdon, CR ;
Lee, KR ;
Hanson, AE ;
Elder, JR ;
Harris, WH .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (03) :349-358
[10]
Minimum Ten-Year Results of a Porous Acetabular Component for Crowe I to III Hip Dysplasia Using an Elevated Hip Center [J].
Kaneuji, Ayumi ;
Sugimori, Tanzo ;
Ichiseki, Toru ;
Yamada, Kengo ;
Fukui, Kiyokazu ;
Matsumoto, Tadami .
JOURNAL OF ARTHROPLASTY, 2009, 24 (02) :187-194