Test of a CMS MSGC tracker prototype in a high-intensity hadron beam

被引:5
作者
Abbaneo, D
Albert, E
Angelini, F
Bastie, C
Beaumont, W
Bell, B
Bellazzini, R
Bozzo, M
Bouhali, O
Boulogne, I
Brand, C
Breuker, H
Brez, A
Brom, JM
Caner, A [1 ]
Castaldi, R
Cattai, A
Chorowicz, V
Fontaine, JC
Giassi, A
Henke, T
Latronico, L
Loreti, M
Lumb, N
Magazzu, C
Malina, R
Manola-Poggioli, E
Martin, J
Massai, M
Moneta, L
Morelli, A
Raffo, R
Ribeiro, R
Sigriest, P
Silvestris, L
Spandre, G
Spezziga, M
Tsirou, A
Van Doninck, W
Van Lancker, L
Verdini, PG
Voltolini, C
Zghiche, A
Zhukov, V
机构
[1] European Org Nucl Res, CH-1211 Geneva 23, Switzerland
[2] Univ Pisa, Pisa, Italy
[3] Ist Nazl Fis Nucl, Pisa, Italy
[4] Inter Univ Instelling Antwerpen, UIA, Antwerp, Belgium
[5] ULD VUB, Inter Univ High Energies, Brussels, Belgium
[6] Inter Univ Mons Hainaut, UMH, Mons, Belgium
[7] Inst Rech Subatom, Strasbourg, France
[8] Inst Phys Nucl Lyon, Villeurbanne, France
[9] Univ Haut Alsace, GRPHE, Mulhouse, France
[10] Univ Padua, Padova, Italy
[11] Ist Nazl Fis Nucl, Padova, Italy
[12] Univ Genoa, Genova, Italy
[13] Ist Nazl Fis Nucl, I-16146 Genova, Italy
关键词
D O I
10.1016/S0168-9002(97)01230-8
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A set of CMS MicroStrip Gas Chambers (MSGC) was exposed to a high-intensity 3 GeV/c pion beam at a CERN PS facility for a period of two weeks. The performance of the detectors is reported in terms of stability of efficiency and response to minimum ionising particles as well as to more heavily ionising fragments generated by nuclear interactions. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:37 / 42
页数:6
相关论文
共 9 条
[1]   Performance of a prototype of the microstrip gas chambers for the CMS experiment at LHC [J].
Albert, E ;
Angelini, A ;
Bastie, C ;
Bell, B ;
Bellazzini, R ;
Bozzo, M ;
Brand, C ;
Brez, A ;
Caner, A ;
Cattai, A ;
Elliott-Peisert, A ;
Giassi, A ;
Magazzu, C ;
Malina, R ;
Manola-Poggioli, E ;
Martin, J ;
Massai, MM ;
Morelli, A ;
Raffo, R ;
Silvestris, L ;
Spandre, G ;
Spezziga, MA ;
Tsirou, A ;
Verdini, PG .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3) :70-72
[2]  
BELLAZZINI R, 1997081 CMS
[3]  
BELLAZZINI R, UNPUB NUCL INSTR M A
[4]  
CATTAI A, TESTS MSGC ADV PASSI
[5]  
*CMS COLL, 9438 CERN LHCC CMS C
[6]   ABSORPTION CROSS-SECTIONS FOR PIONS, KAONS, PROTONS AND ANTIPROTONS ON COMPLEX NUCLEI IN 6 TO 60 GEV-C MOMENTUM RANGE [J].
DENISOV, SP ;
DONSKOV, SV ;
GORIN, YP ;
KRASNOKUTSKY, RN ;
PETRUKHIN, AI ;
PROKOSHKIN, YD ;
STOYANOVA, DA .
NUCLEAR PHYSICS B, 1973, B 61 (SEP24) :62-76
[7]  
JONES LL, 1994, PREMUX 128 SPECIFICA
[8]  
KLAUS G, 9633 CRN LEPSI
[9]  
SACHDEVA R, 1994, TN94215 CMS