Analysis and design of lapped connections between cold-formed steel Z sections

被引:34
作者
Chung, KF [1 ]
Ho, HC [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Civil & Struct Engn, Kowloon, Hong Kong, Peoples R China
关键词
cold-formed steel beam members; design development on lapped Z sections; multi-span purlins; bolted moment connections; combined bending and shear; effective flexural rigidities;
D O I
10.1016/j.tws.2004.11.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an analysis and design method for lapped connections between cold-formed steel Z sections after careful calibration against test data obtained from a total of 26 one point-load tests on lapped connections. Based on the experimental observations on the lapped connection tests where combined bending and shear is always critical in the cross-sections at the end of laps, an analysis method is proposed to evaluate all the internal forces within the lapped connections. Once the co-existing moments and shear forces in the lapped connections are evaluated, the critical sections are readily checked against combined bending and shear using codified design rules. Moreover, design expressions are also proposed for the evaluation of effective flexural rigidities of lapped connections with various bolt configurations against practical lap length to section depth ratios. Consequently, the structural behaviour of lapped sections between cold-formed steel Z sections in terms of strength and stiffness is quantified rationally for general design. The research project aims to provide understanding to the structural performance of lapped connections between cold-formed steel Z sections, and hence, to develop a set of rational design rules for multi-span purlin systems with overlaps in modern roof construction. (C) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1071 / 1090
页数:20
相关论文
共 18 条
  • [1] *AM IR STEEL I, 1997, SPEC DES COLD FORM S
  • [2] *BRIT STAND I, 1998, BS5950 BRIT STAND 5
  • [3] Structural performance of modern roofs with thick over-purlin insulation - Experimental investigation
    Chung, KF
    StQuinton, D
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 40 (01) : 17 - 38
  • [4] Epstein HI, 1998, PRACT PERIOD STRUCT, V3, P60, DOI [DOI 10.1061/(ASCE)1084-0680(1998)3:2(60), 10.1061/]
  • [5] *EUR COMM STAND EU, 2002, DES STEEL STRUCT 1 3
  • [6] ANALYSIS AND DESIGN OF LIGHT GAUGE STEEL ROOF SYSTEMS
    FENSKE, TE
    YENER, M
    [J]. THIN-WALLED STRUCTURES, 1990, 10 (03) : 221 - 234
  • [7] Load capacity of nested, laterally braced, cold-formed steel Z-section beams
    Ghosn, AA
    Sinno, RR
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1996, 122 (08): : 968 - 971
  • [8] GOVERNING STRESSES IN Z-PURLIN LAP JOINTS
    GHOSN, AA
    SINNO, RR
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1995, 121 (12): : 1735 - 1741
  • [9] Hancock G.J., 2001, COLD FORMED STEEL ST
  • [10] Hancock GJ, 1993, AUSTR CIVIL ENG T, V35, P221