Evaluation of proscriptive health care policy implementation in screening mammography

被引:14
作者
Beam, CA [1 ]
Conant, EF [1 ]
Sickles, EA [1 ]
Weinstein, SP [1 ]
机构
[1] H Lee Moffitt Canc Ctr & Res Inst, Tampa, FL 33612 USA
关键词
breast radiography; utilization; diagnostic radiology; observer performance; radiology and radiologists; departmental management;
D O I
10.1148/radiol.2292021585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the potential effect of proscriptive health care policies directed toward improving screening mammogram interpretation in the United States. MATERIALS AND METHODS: Percentiles of accuracy based on a random sample of 110 U.S. radiologists were used to examine the number of radiologists who would need to be restricted from providing mammographic interpretation to increase median accuracy from 66% to 67%, 71%, and 76%. In addition, reading volume data recorded for the sampled readers were used to project the percentage reduction in service volume (mammograms per year) that would result from restriction. Characteristics of participating radiologists were compared with those of nonparticipating radiologists by using x(2) testing and analysis of variance to assess the external validity of the results. RESULTS: To increase median accuracy by 1% (from 66% to 67%) would require prohibiting about 2,200 U.S. radiologists (ie, the 11% in the lowest quantile for accuracy) from performing mammographic interpretation and would result in a reduction of yearly service volume of approximately 10%. An increase in median accuracy of 5% (to 71%) would require prohibiting about 6,000 U.S. radiologists (ie, 30%) from performing this service, with an accompanying volume reduction of 25%. An increase in median accuracy of 10% (to 77%) would require prohibiting about 11,400 practicing U.S. radiologists (ie, 57%) from performing this service and would diminish the national service capacity by 50%. CONCLUSION: These data show that implementation of proscriptive health care policies based on accuracy would diminish the service capacity of screening mammography in the United States. (C) RSNA, 2003.
引用
收藏
页码:534 / 540
页数:7
相关论文
共 19 条
[1]   Association of volume and volume-independent factors with accuracy in screening mammogram interpretation [J].
Beam, CA ;
Conant, EF ;
Sickles, EA .
JOURNAL OF THE NATIONAL CANCER INSTITUTE, 2003, 95 (04) :282-290
[2]   Variability in the interpretation of screening mammograms by US radiologists - Findings from a national sample [J].
Beam, CA ;
Layde, PM ;
Sullivan, DC .
ARCHIVES OF INTERNAL MEDICINE, 1996, 156 (02) :209-213
[3]   A two-stage ROC curve regression model when sampling a population of diagnosticians [J].
Beam, CA .
MEDICAL IMAGING 2002: IMAGE PERCEPTION, OBSERVER PERFORMANCE, AND TECHNOLOGY ASSESSMENT, 2002, 4686 :236-247
[4]  
D'Orsi CJ, 1998, ILLUSTRATED BREAST I
[5]   DISTRIBUTION OF MATHEMATICAL SOFTWARE VIA ELECTRONIC MAIL [J].
DONGARRA, JJ ;
GROSSE, E .
COMMUNICATIONS OF THE ACM, 1987, 30 (05) :403-407
[6]   Context bias - A problem in diagnostic radiology [J].
Egglin, TKP ;
Feinstein, AR .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1996, 276 (21) :1752-1755
[7]  
Elmore JG, 2002, J NATL CANCER I, V94, P321
[8]  
Esserman L, 2002, JNCI-J NATL CANCER I, V94, P369
[9]   THE MEANING AND USE OF THE AREA UNDER A RECEIVER OPERATING CHARACTERISTIC (ROC) CURVE [J].
HANLEY, JA ;
MCNEIL, BJ .
RADIOLOGY, 1982, 143 (01) :29-36
[10]   A receiver operating: Characteristic partial area index for highly sensitive diagnostic tests [J].
Jiang, YL ;
Metz, CE ;
Nishikawa, RM .
RADIOLOGY, 1996, 201 (03) :745-750