Increased throughput in quantitative bioanalysis using parallel-column liquid chromatography with mass spectrometric detection

被引:27
作者
Jemal, M [1 ]
Huang, M [1 ]
Mao, Y [1 ]
Whigan, D [1 ]
Powell, ML [1 ]
机构
[1] Bristol Myers Squibb Co, Pharmaceut Res Inst, Bioanal Res Metab & Pharmacokinet, New Brunswick, NJ 08903 USA
关键词
D O I
10.1002/rcm.330
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The feasibility of quantitative bioanalysis by parallel-column liquid chromatography in conjunction with a conventional single-source electrospray mass spectrometer has been investigated using plasma samples containing a drug and its three metabolites. Within a single chromatographic run time, sample injections were made alternately onto each of two analytical columns in parallel at specified intervals, with a mass spectrometer data file opened at every injection. Thus, the mass spectrometer collected data from two sample injections into separate data files within a single chromatographic run time. Therefore, without sacrificing the chromatographic separation or the selected reaction monitoring (SRM) dwell time, the sample throughput was increased by a factor of two. Comparing the method validation results obtained using the two-column system with those obtained using the corresponding conventional single-column approach, the methods on the two systems were found to be equivalent in terms of accuracy and precision. The parallel-column system is simple and can be implemented using existing laboratory equipment with no additional capital outlays. A parallel-column system configured in this manner can be used not only for the within-a-run analysis of two samples containing two different sets of chemical entities, but also for the within-a-run analysis of two samples containing the same set of chemical entities. Copyright (C) 2001 John Wiley & Sons, Ltd.
引用
收藏
页码:994 / 999
页数:6
相关论文
共 49 条
[1]  
Allanson JP, 1996, RAPID COMMUN MASS SP, V10, P811, DOI 10.1002/(SICI)1097-0231(199605)10:7<811::AID-RCM561>3.0.CO
[2]  
2-Q
[3]  
[Anonymous], RAPID COMMUN MASS SP
[4]  
Ayrton J, 1999, RAPID COMMUN MASS SP, V13, P1657, DOI 10.1002/(SICI)1097-0231(19990830)13:16<1657::AID-RCM694>3.0.CO
[5]  
2-L
[6]   Optimisation and routine use of generic ultra-high flow-rate liquid chromatography with mass spectrometric detection for the direct on-line analysis of pharmaceuticals in plasma [J].
Ayrton, J ;
Dear, GJ ;
Leavens, WJ ;
Mallett, DN ;
Plumb, RS .
JOURNAL OF CHROMATOGRAPHY A, 1998, 828 (1-2) :199-207
[7]  
Ayrton J, 1997, RAPID COMMUN MASS SP, V11, P1953, DOI 10.1002/(SICI)1097-0231(199712)11:18<1953::AID-RCM102>3.0.CO
[8]  
2-Z
[9]  
Bayliss MK, 2000, RAPID COMMUN MASS SP, V14, P2039, DOI 10.1002/1097-0231(20001115)14:21<2039::AID-RCM130>3.0.CO
[10]  
2-2