Ultratrace determination of lead, cadmium and copper in environmental and biological samples by atomic absorption spectrometry after their separation and preconcentration using octadecyl silica membrane disks modified with a new N-S Schiff base

被引:19
作者
Ganjali, MR
Basiripour, F
Shamsipur, M
Hashemi, OR
Moghimi, A
Aghabozorg, H
机构
[1] Univ Tehran, Dept Chem, Tehran, Iran
[2] Kermanshah Univ, Dept Chem, Kermanshah, Iran
[3] Tarbiat Modares Univ, Dept Chem, Tehran, Iran
[4] Imam Hosshin Univ, Dept Chem, Tehran, Iran
[5] Tarbiat Moallem Univ, Dept Chem, Tehran, Iran
关键词
copper(II); cadmium(II); lead(II); solid-phase extraction; S-N Schiff base; SOLID-PHASE EXTRACTION; SPECTROPHOTOMETRIC DETERMINATION; TRACE AMOUNTS; METAL-IONS; NICKEL; COBALT; ENRICHMENT; WATERS; RESINS; ZINC;
D O I
10.1080/03067310001608786
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Pb(II), Cd(II) and Cu(II) ions were separated and preconcentrated by solid-phase extraction on octadecyl-bonded silica membrane disks modified with a new S-N-containing Schiff base ( bis -2-thiophenal propandiamine) (BTPD) followed by elution and atomic absorption spectrometric detection. The method was applied as a separation and detection method for lead(II), cadmium(II) and copper(II) in environmental and biological samples. Extraction efficiency and the influence of sample matrix, flow rate, pH, and type and minimum amount of stripping acid were investigated. The maximum capacity of the membrane disks modified by 4 mg of BTPD was found to be 668 +/- 10, 480 +/- 8 and 454 +/- 7 mug of lead, cadmium and copper, respectively. The limit of detection of the proposed method is 0.25, 0.01 and 0.02 ng/mL for lead, cadmium and copper, respectively.
引用
收藏
页码:997 / 1008
页数:12
相关论文
共 46 条
[1]  
[Anonymous], 1980, ANAL CHEM, V52, P2242
[2]  
[Anonymous], 1996, Information of Mark Orlic, U.S. EPA
[3]   CESIUM-SELECTIVE POLY(VINYL CHLORIDE) MEMBRANE ELECTRODES BASED ON CALIX[6]ARENE ESTERS [J].
CADOGAN, A ;
DIAMOND, D ;
SMYTH, MR ;
SVEHLA, G ;
MCKERVEY, MA ;
SEWARD, EM ;
HARRIS, SJ .
ANALYST, 1990, 115 (09) :1207-1210
[5]   Flotation separation of cobalt and copper from fresh waters and their determination by electrothermal atomic absorption spectrometry [J].
Cundeva, K ;
Stafilov, T ;
Pavlovska, G .
MICROCHEMICAL JOURNAL, 2000, 65 (02) :165-175
[6]   CHARACTERIZATION OF CALCIUM FORM OF CHELEX-100 FOR TRACE-METAL STUDIES [J].
FIGURA, P ;
MCDUFFIE, B .
ANALYTICAL CHEMISTRY, 1977, 49 (13) :1950-1953
[7]   COPPER TOXICITY AND CHEMISTRY IN THE ENVIRONMENT - A REVIEW [J].
FLEMMING, CA ;
TREVORS, JT .
WATER AIR AND SOIL POLLUTION, 1989, 44 (1-2) :143-158
[8]  
FRIBERG L, 1986, HDB TOXICOLOGY METAL, V1, P11
[9]  
Ganjali MR, 1998, J CHEM SOC FARADAY T, V94, P1959
[10]  
Ganjali MR, 2002, CHEM ANAL-WARSAW, V47, P619