Effectiveness of operative treatment of internal orbital wall fracture with polydioxanone implant

被引:87
作者
Kontio, R
Suuronen, R
Salonen, O
Paukku, P
Konttinen, YT
Lindqvist, C
机构
[1] Univ Helsinki, Cent Hosp, Dept Oral & Maxillofacial Surg, SF-00130 Helsinki, Finland
[2] Univ Helsinki, Cent Hosp, Dept Radiol, SF-00130 Helsinki, Finland
[3] Univ Helsinki, Dept Oral Med, Helsinki, Finland
[4] Univ Helsinki, Dept Anat, Helsinki, Finland
关键词
reconstruction; orbit; biodegradable implant;
D O I
10.1054/ijom.2001.0067
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Many implants, some made from teflon or silicone, have been used for internal orbital wall reconstruction. Late complications relating to use of such implants have been reported. In this prospective study a polydioxanone (PDS) implant absorbable in vivo was used for internal orbital wall reconstruction. Follow-up involved clinical examination, magnetic resonance imaging (MRI) and computerized tomography (CT). Clinical examinations were undertaken before operation and up to 36 weeks postoperatively. Sixteen consecutive patients (10 pure blow-out fractures. six with associated zygomatic fracture) took part in the study. Prevalences of diplopia, proptosis and enophthalmus were recorded during each follow-up examination. This study revealed no muscle entrapment within the fracture line. Although CT results confirmed bone growth in the internal orbital wall, shape was unsatisfactory, and orbital volume was not reduced. MR[ revealed thick scar formations in six cases (37.5%), fibrotic sinuses filled with air or gas in three cases (19%) and a fibrotic sinus with fluid around the PDS in one case (6%). Our results suggest that use of PDS in reconstructing the internal orbital wall is inadvisable.
引用
收藏
页码:278 / 285
页数:8
相关论文
共 25 条
[1]  
Bar B W, 1992, Aktuelle Traumatol, V22, P229
[2]   BLOW-OUT FRACTURE OF THE ORBIT - DIAGNOSTIC AND THERAPEUTIC CONSIDERATIONS, AND RESULTS IN 90 PATIENTS TREATED [J].
BARTKOWSKI, SB ;
KRZYSTKOWA, KM .
JOURNAL OF MAXILLOFACIAL SURGERY, 1982, 10 (03) :155-164
[3]   FOREIGN-BODY REACTIONS TO RESORBABLE POLY(L-LACTIDE) BONE PLATES AND SCREWS USED FOR THE FIXATION OF UNSTABLE ZYGOMATIC FRACTURES [J].
BERGSMA, EJ ;
ROZEMA, FR ;
BOS, RRM ;
DEBRUIJN, WC .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1993, 51 (06) :666-670
[4]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[5]  
CANTALOUBE D, 1989, REV STOMATOL CHIR, V90, P48
[6]  
CONVERSE J M, 1957, Br J Plast Surg, V9, P265
[7]  
CUTRIGHT DE, 1972, ORAL SURG ORAL MED O, V33, P28, DOI 10.1016/0030-4220(72)90204-6
[8]   FRACTURES OF THE ORBITAL FLOOR - INDICATIONS FOR EXPLORATION AND FOR THE USE OF A FLOOR IMPLANT [J].
DEMAN, K .
JOURNAL OF MAXILLOFACIAL SURGERY, 1984, 12 (02) :73-77
[9]  
DEROCHE R, 1998, MUND KIEFER GESIC S1, V2, P117
[10]  
EMERY J M, 1971, Transactions of the American Academy of Ophthalmology and Oto-Laryngology, V75, P802