Long-term biomechanical stability and clinical improvement after extended multilevel corpectomy and circumferential reconstruction of the cervical spine using titanium mesh cages

被引:59
作者
Acosta, Frank L., Jr. [1 ]
Aryan, Henry E. [1 ]
Chou, Dean [1 ]
Ames, Christopher P. [1 ]
机构
[1] Univ Calif San Francisco, Dept Neurol Surg, San Francisco, CA 94143 USA
来源
JOURNAL OF SPINAL DISORDERS & TECHNIQUES | 2008年 / 21卷 / 03期
关键词
cervical spine; multilevel corpectomy; spinal fusion; titanium mesh cage; biomechanical stability; spinal instrumentation;
D O I
10.1097/BSD.0b013e3180654205
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design: Retrospective review of clinical case series Objective: We present our experience with extended ( 3 levels) anterior cervical corpectomy (EACC) and reconstruction. Summary of Background Data: Multilevel cervical corpectomy has traditionally been associated with increased graft-related complications and worse clinical outcomes compared with single-level procedures. Data specifically regarding corpectomies across 3 or more levels remains limited. Methods: Retrospective review of data on 20 patients who underwent anterior cervical corpectomies with titanium mesh cage reconstruction and supplemental posterolateral fixation across 3 or more levels of the cervical spine. Anteroposterior/lateral plain films were used to determine sagittal balance and cage subsidence. Fusion was defined as the lack of motion on flexion-extension radiographs. Patients underwent preoperative and postoperative clinical assessment using visual analog scores and Nurick grading. Results: Surgery was performed for spondylotic myelopathy in 15 patients, osteomyelitis in 4, and fracture in 1. Corpectomies were performed across an average of 3.4 levels. Average follow-up was 33 months. Local autograft was used in all cases except osteomyelitis, where allograft was used instead. Sagittal balance was improved or maintained in all patients and was not related to number of corpectomy levels. An average of 30.2 degrees of kyphosis correction was achieved in 9 patients. All patients demonstrated radiographic evidence of fusion without significant cage subsidence and no cases of instrumentation failure. Improvement in pain and functional scores occurred in all cases. Conclusions: Circumferential reconstruction using titanium mesh cages after EACC can provide appropriate, biomechanically stable fixation and allows for significant correction of preexisting kyphosis. Supplemental posterior instrumentation may limit delayed cage subsidence and loss of sagittal balance after this procedure. EACC and circumferential reconstruction seems to be an effective treatment for symptomatic degenerative, traumatic, or infectious pathology involving 3 or more levels of the anterior cervical spine.
引用
收藏
页码:165 / 174
页数:10
相关论文
共 69 条
[1]
Successful outcome of six-level cervicothoracic corpectomy and circumferential reconstruction: Case report and review of literature on multilevel cervicothoracic corpectomy [J].
Acosta Jr. F.L. ;
Aryan H.E. ;
Ames C.P. .
European Spine Journal, 2006, 15 (Suppl 5) :S670-S674
[2]
COMPARISON BETWEEN ALLOGRAFT PLUS DEMINERALIZED BONE-MATRIX VERSUS AUTOGRAFT IN ANTERIOR CERVICAL FUSION - A PROSPECTIVE MULTICENTER STUDY [J].
AN, HS ;
SIMPSON, JM ;
GLOVER, JM ;
STEPHANY, J .
SPINE, 1995, 20 (20) :2211-2216
[3]
STABILIZATION OF THE CERVICAL SPINE BY ANTERIOR FUSION [J].
BAILEY, RW ;
BADGLEY, CE .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1960, 42 (04) :565-594
[4]
Incidence of dysphagia after anterior cervical spine surgery - A prospective study [J].
Bazaz, R ;
Lee, MJ ;
Yoo, JU .
SPINE, 2002, 27 (22) :2453-2458
[5]
BERNARD TN, 1987, CLIN ORTHOP RELAT R, P149
[6]
Operative management of metastatic and malignant primary subaxial cervical tumors [J].
Bilsky, MH ;
Boakye, M ;
Collignon, F ;
Kraus, D ;
Boland, P .
JOURNAL OF NEUROSURGERY-SPINE, 2005, 2 (03) :256-264
[7]
ROBINSON ANTERIOR CERVICAL DISKECTOMY AND ARTHRODESIS FOR CERVICAL RADICULOPATHY - LONG-TERM FOLLOW-UP OF 100 AND 22 PATIENTS [J].
BOHLMAN, HH ;
EMERY, SE ;
GOODFELLOW, DB ;
JONES, PK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (09) :1298-1307
[8]
BONI M, 1984, SPINE, V9, P358, DOI 10.1097/00007632-198405000-00005
[9]
MODIFIED SMITH-ROBINSON PROCEDURE FOR ANTERIOR CERVICAL DISCECTOMY AND FUSION [J].
BRODKE, DS ;
ZDEBLICK, TA .
SPINE, 1992, 17 (10) :S427-S430
[10]
Dynamic cervical plates - Biomechanical evaluation of load sharing and stiffness [J].
Brodke, DS ;
Gollogly, S ;
Mohr, RA ;
Nguyen, BK ;
Dailey, AT ;
Bachus, KN .
SPINE, 2001, 26 (12) :1324-1329