Determination of subnanogram concentrations of fentanyl in plasma by gas chromatography mass spectrometry: Comparison with standard radioimmunoassay

被引:29
作者
Fryirsa, B
Woodhouse, A
Huang, JL
Dawson, M
Mather, LE
机构
[1] UNIV SYDNEY, ROYAL N SHORE HOSP, DEPT ANAESTHESIA & PAIN MANAGEMENT, ST LEONARDS, NSW 2065, AUSTRALIA
[2] NORVET LABS PTY LTD, N RYDE, NSW 2113, AUSTRALIA
[3] UNIV TECHNOL SYDNEY, DEPT CHEM, SYDNEY, NSW 2007, AUSTRALIA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1997年 / 688卷 / 01期
关键词
fentanyl;
D O I
10.1016/S0378-4347(97)88058-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was devised to determine fentanyl plasma concentrations by GC-MS using selected-ion monitoring (SIM) with sufentanil as internal standard. This was compared with a commonly used commercial radioimmunoassay (RIA). Sample preparation for GC-MS involved basification of plasma then extraction using n-butyl chloride followed by concentration to dryness and reconstitution in toluene for chromatography. Using 1-ml plasma samples, the estimated limit of detection of fentanyl was 20 pg/ml. Blood samples for pharmacokinetic studies were split and assayed by GC-MS and RIA which had a limit of detection of 200 pg/ml. Pearson's r (r=0.80, p<0.0001) indicated the methods were highly correlated at all plasma concentrations, Owing to the greater sensitivity of the method, GC-MS is recommended over RIA for subnanogram determination of fentanyl in plasma.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 20 条
[1]   TISSUE DISTRIBUTION OF FENTANYL AND ALFENTANIL IN THE RAT CANNOT BE DESCRIBED BY A BLOOD-FLOW LIMITED MODEL [J].
BJORKMAN, S ;
STANSKI, DR ;
HARASHIMA, H ;
DOWRIE, R ;
HARAPAT, SR ;
WADA, DR ;
EBLING, WF .
JOURNAL OF PHARMACOKINETICS AND BIOPHARMACEUTICS, 1993, 21 (03) :255-279
[2]   COMPARATIVE TISSUE CONCENTRATION PROFILES OF FENTANYL AND ALFENTANIL IN HUMANS PREDICTED FROM TISSUE BLOOD PARTITION DATA OBTAINED IN RATS [J].
BJORKMAN, S ;
STANSKI, DR ;
VEROTTA, D ;
HARASHIMA, H .
ANESTHESIOLOGY, 1990, 72 (05) :865-873
[3]  
CAMPISTRON G, 1988, CLIN CHEM, V34, P2157
[4]   FENTANYL AND THE METABOLIC RESPONSE TO SURGERY [J].
HALL, GM .
BRITISH JOURNAL OF ANAESTHESIA, 1980, 52 (06) :561-562
[5]  
Janssen P.A., 1985, OPIOIDS ANESTHESIA, P37
[6]   SENSITIVE GAS-LIQUID-CHROMATOGRAPHY METHOD FOR THE DETERMINATION OF FENTANYL CONCENTRATIONS IN BLOOD [J].
KOWALSKI, SR ;
GOURLAY, GK ;
CHERRY, DA ;
MCLEAN, CF .
JOURNAL OF PHARMACOLOGICAL METHODS, 1987, 18 (04) :347-355
[7]   DETERMINATION OF FENTANYL AND ALFENTANIL IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ULTRAVIOLET DETECTION [J].
KUMAR, K ;
MORGAN, DJ ;
CRANKSHAW, DP .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 :464-468
[8]  
MATHER LE, 1991, PHARMACOKINETICS FEN, P73
[9]  
MCDONALD J, 1987, RES COMMUN CHEM PATH, V57, P389
[10]   DETECTION OF PICOGRAM CONCENTRATIONS OF FENTANYL IN PLASMA BY GAS-LIQUID-CHROMATOGRAPHY [J].
PHIPPS, JA ;
SABOURIN, MA ;
BUCKINGHAM, W ;
STRUNIN, L .
JOURNAL OF CHROMATOGRAPHY, 1983, 272 (02) :392-395