Application of the off-gas method to the measurement of oxygen transfer in biofilters

被引:16
作者
Gillot, S
Kies, F
Amiel, C
Roustan, M
Héduit, A
机构
[1] Irstea, F-92163 Antony, France
[2] INSA, LIPE, F-31077 Toulouse, France
关键词
aeration; biofilter; clean water; oxygen mass transfer; sulphite oxidation;
D O I
10.1016/j.ces.2005.04.056
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To determine the oxygen mass transfer in clean water in biofilters, a method based on the follow up of the oxygen fraction in the off gas during the oxidation of sulphite in excess has been evaluated and applied to a pilot-scale unit (250 L, superficial gas velocity from 0 to 5.6 x 10(-3) m(N) s(-1), superficial liquid velocity from 0 to 2.5 x 10(-3) m s(-1)). Tests performed on a two-phase reactor showed that, without any cobalt addition, standard oxygen transfer efficiencies (SOTE) obtained from the proposed method are not statistically different from those issued from the standardised method. A relationship has been proposed to express SOTE values as a function of the conductivity, and the influence of the gas and liquid velocities on SOTE and k(L)a has been investigated. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6336 / 6345
页数:10
相关论文
共 29 条
[1]   Toward a method for measuring oxygen transfer in biofilters [J].
Amiel, C ;
Gillot, S ;
Roustan, M ;
Héduit, EA .
WATER QUALITY RESEARCH JOURNAL OF CANADA, 2002, 37 (04) :729-743
[2]  
AMIEL C, 2002, THESIS INSA TOULOUSE
[3]  
*ASCE, 1992, ASCE STAND MEAS OX T
[4]  
BAILLOD CR, 1986, J WATER POLLUT CON F, V58, P290
[5]   BIOLOGICAL AERATED FILTERS - ASSESSMENT OF THE PROCESS-BASED ON 12 SEWAGE-TREATMENT PLANTS [J].
CANLER, JP ;
PERRET, JM .
WATER SCIENCE AND TECHNOLOGY, 1994, 29 (10-11) :13-22
[6]   Comparison of oxygen-transfer measurement methods under process conditions [J].
Capela, S ;
Gillot, S ;
Héduit, A .
WATER ENVIRONMENT RESEARCH, 2004, 76 (02) :183-188
[7]   Volumetric oxygen mass transfer coefficient in an upflow cocurrent packed-bed bioreactor [J].
Deront, M ;
Samb, FM ;
Adler, N ;
Peringer, P .
CHEMICAL ENGINEERING SCIENCE, 1998, 53 (07) :1321-1330
[8]   SIMULTANEOUS MEASUREMENT OF INTERFACIAL AREA AND MASS-TRANSFER COEFFICIENT IN 3-PHASE FLUIDIZED-BEDS [J].
DHANUKA, VR ;
STEPANEK, JB .
AICHE JOURNAL, 1980, 26 (06) :1029-1038
[9]  
EWING L, 1988, 61 ANN WPCF C DALL T
[10]   Predicting oxygen transfer of fine bubble diffused aeration systems-model issued from dimensional analysis [J].
Gillot, S ;
Capela-Marsal, S ;
Roustan, M ;
Héduit, A .
WATER RESEARCH, 2005, 39 (07) :1379-1387