Can radiant floor heating systems be used in removable glazed enclosed patios meeting thermal comfort standards?

被引:23
作者
Garcia, Davide Astiaso [1 ]
机构
[1] Univ Roma La Sapienza, DIAEE Dept Astronaut Energet & Elect Engn, Corso Vittorio Emanuele II 244, I-00186 Rome, Italy
关键词
Underfloor heating; Glazed enclosed patios; Thermal comfort; Radiant floor heating panels; Floor surface temperature; Heat transfer efficiency; PHASE-CHANGE MATERIAL; CHP COMBINED HEAT; ENERGY-SOURCES; PUMP SYSTEM; SIMULATION; OPTIMIZATION; PERFORMANCE; RADIATION; PRESSURE; IMPACTS;
D O I
10.1016/j.buildenv.2016.07.013
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Many systems are used for heating glazed enclosed patios of restaurants, pubs or other restaurant businesses. This paper explores the possibilities of use radiant floor heating systems (RFHS) in removable glazed enclosed patios maintaining thermal comfort in terms of predicted percentage of dissatisfied (PPD) and predicted mean vote (PMV) optimal ranges. The effects of different envelope structures of glazed enclosed patios on floor surface temperature using a radiant floor heating system have been analyzed. In addition, considering the use of removable and modular radiant floor heating panels, delivery and return pipes layouts from a heat power generator to each single radiant floor heating panel have been analyzed assessing flow velocity and pressure drops in order to pinpoint the best layout for optimizing heat transfer efficiency and energy saving. The findings showed at assumed outdoor and indoor temperatures what are the considered glazed enclosed patio envelopes that allow the use of a RFHS maintaining the floor surface temperature within thermal comfort ranges and avoiding local thermal discomfort due to floor temperature and vertical radiation asymmetry. Moreover, the flow velocity and concentrated/distributed pressure drops analysis pinpointed optimal pipe layouts for connecting heat power generator to each underfloor heating panel. concluding, the paper highlighted that, up to meet thermal comfort standards, under floor heating systems could be used for heating glazed enclosed patios only for certain envelope structures. Additionally, a delivery and return pipe layout should be properly designed for minimizing pressure drops and optimize heat transfer efficiency. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:378 / 388
页数:11
相关论文
共 37 条
[1]  
[Anonymous], 2003, 128312003 EN EUR COM
[2]  
[Anonymous], 2001, ASHRAE fundamentals handbook
[3]  
[Anonymous], 2009, ASHRAE Handbook|Fundamentals
[4]   Simulation-based model predictive control by the multi-objective optimization of building energy performance and thermal comfort [J].
Ascione, Fabrizio ;
Bianco, Nicola ;
De Stasio, Claudio ;
Mauro, Gerardo Maria ;
Vanoli, Giuseppe Peter .
ENERGY AND BUILDINGS, 2016, 111 :131-144
[5]  
ATHIENITIS AK, 1993, ASHRAE TRAN, V99, P1049
[6]   Comparative study for under-floor heating using solar collectors or solar ponds [J].
Badran, AA ;
Hamdan, MA .
APPLIED ENERGY, 2004, 77 (01) :107-117
[7]   Comparison between ASHRAE and ISO thermal transmittance calculation methods [J].
Blanusa, Petar ;
Goss, William P. ;
Roth, Hartwig ;
Weitzmannn, Peter ;
Jensen, Claus F. ;
Svendsen, Svend ;
Elmahdy, Hakim .
ENERGY AND BUILDINGS, 2007, 39 (03) :374-384
[8]   Decreasing energy use and influence to environment by radiant panel heating using different energy sources [J].
Bojic, Milorad ;
Cvetkovic, Dragan ;
Bojic, Ljubisa .
APPLIED ENERGY, 2015, 138 :404-413
[9]   Building integrated bioenergy production (BIBP): Economic sustainability analysis of Bari airport CHP (combined heat and power) upgrade fueled with bioenergy from short chain [J].
de Santoli, Livio ;
Mancini, Francesco ;
Nastasi, Benedetto ;
Piergrossi, Valentina .
RENEWABLE ENERGY, 2015, 81 :499-508
[10]  
FANGER PO, 1986, ASHRAE J, V28, P33