Laser optoacoustic imaging of breast cancer in vivo

被引:106
作者
Oraevsky, AA [1 ]
Karabutov, AA [1 ]
Solomatin, SV [1 ]
Savateeva, EV [1 ]
Andreev, VG [1 ]
Gatalica, Z [1 ]
Singh, H [1 ]
Fleming, RD [1 ]
机构
[1] Univ Texas, Med Branch, Ctr Biomed Engn, Galveston, TX 77555 USA
来源
BIOMEDICAL OPTOACOUSTICS II | 2001年 / 4256卷
关键词
optoacoustic imaging; breast cancer; ultrawide-band acoustic transducer; laser; ultrasound;
D O I
10.1117/12.429300
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A clinical prototype of the laser optoacoustic imaging system (LOIS) was employed for breast cancer detection and localization in patients with confirmed breast cancer and scheduled for radical mastectomy. The prototype LOIS used a single optical fiber for delivery of laser pulses, an arc shaped 32-element PVDF transducer array for ultrawide-band piezoelectric detection of optoacoustic signals and a single-channel data acquisition card for signal processing. The resonance ultrasound frequency of the 110 mum PVDF film was outside detectable range of ultrasound. Spatial resolution of the transducer array was slightly better than lmm in radial direction and slightly worse than 1 mm in lateral direction. The system was optimized for contrast and sensitivity. Data acquisition, signal conditioning and image processing were significantly improved and optimized resulting in reduced image frame rate of 2 seconds employing 700 MHz Aphlon processor. The computer code for digital signal processing employed band-pass hyper-Gaussian filtering and denoising. An automatic recognition of the optoacoustic signal detected from the irradiated surface was implemented in order to visualize the breast surface and improve the accuracy of tumor localization. Radial back-projection algorithm was employed adopting combination of integration along spherical wavefronts and integration along planar wavefronts (as in Radon transform) for image reconstruction. The system performance was evaluated initially in breast tissue-like phantoms with embedded blood vessels. Clinical studies in breast cancer patients scheduled for surgical mastectomy were performed and compared with xray radiography, ultrasound and pathology reports.
引用
收藏
页码:6 / 15
页数:10
相关论文
共 21 条
[1]   Opto-acoustic tomography of breast cancer with arc-array-transducer [J].
Andreev, VG ;
Karabutov, AA ;
Solomatin, SV ;
Savateeva, EV ;
Aleynikov, V ;
Zhulina, YV ;
Fleming, RD ;
Oraevsky, AA .
BIOMEDICAL OPTOACOUSTICS, 2000, 3916 :36-47
[2]   Laser optoacoustic imaging for breast cancer diagnostics: Limit of detection and comparison with X-ray and ultrasound imaging [J].
Esenaliev, RO ;
Karabutov, AA ;
Tittel, FK ;
Fornage, BD ;
Thomsen, SL ;
Stelling, C ;
Oraevsky, AA .
OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE: THEORY, INSTRUMENTATION, MODEL, AND HUMAN STUDIES II, PROCEEDINGS OF, 1997, 2979 :71-82
[3]   Sensitivity of laser opto-acoustic imaging in detection of small deeply embedded tumors [J].
Esenaliev, RO ;
Karabutov, AA ;
Oraevsky, AA .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :981-988
[4]   Measurement of optical transport properties of normal and malignant human breast tissue [J].
Ghosh, N ;
Mohanty, SK ;
Majumder, SK ;
Gupta, PK .
APPLIED OPTICS, 2001, 40 (01) :176-184
[5]  
Karabutov AA, 1996, APPL PHYS B-LASERS O, V63, P545
[6]  
KARABUTOV AA, 2000, P SOC PHOTO-OPT INS, V3916, P228
[7]  
KINO G, 1987, ACOUSTICS WAVES DEVI
[8]   PHOTOACOUSTIC ULTRASOUND - PULSE PRODUCTION AND DETECTION IN 0.5-PERCENT LIPOSYN [J].
KRUGER, RA ;
LIU, PY .
MEDICAL PHYSICS, 1994, 21 (07) :1179-1184
[9]   PHOTOACOUSTIC ULTRASOUND [J].
KRUGER, RA .
MEDICAL PHYSICS, 1994, 21 (01) :127-131
[10]   Image reconstruction from photoacoustic pressure signals [J].
Liu, PG .
LASER-TISSUE INTERACTION VII, PROCEEDINGS OF, 1996, 2681 :285-296