Amperometric determination of xanthine and hypoxanthine at carbon electrodes. Effect of surface activity and the instrumental parameters on the sensitivity and the limit of detection

被引:33
作者
Cavalheiro, ETG
Brajter-Toth, A [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
[2] Univ Fed Sao Carlos, Dept Quim, BR-13565905 Sao Carlos, SP, Brazil
关键词
xanthine; hypoxanthine; amperometric determination; graphite surface activation; carbon fiber ultramicroelectrodes;
D O I
10.1016/S0731-7085(98)00128-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The performance of active graphite and carbon fiber surfaces produced by different mechanical/electrochemical methods of surface activation has been investigated in the amperometric determinations of xanthine and hypoxanthine under physiologically relevant conditions. The electrodes showed better limits of detection (LOD) when used with differential techniques with a capability of discriminating the analytical signal from the background. Square wave voltammetry and cyclic voltammetry showed the most sensitive response. Electrochemically activated carbon fiber ultramicroelectrodes showed the highest sensitivity (58 A M-1 cm(-2)) and the LOD in the 200 nM range was observed at the rough pyrolytic graphite electrodes by square wave voltammetry. The results demonstrate the feasibility of the development of new electroanalytical methods for the determination of oxypurines in biological samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:217 / 230
页数:14
相关论文
共 38 条
[1]   PURINE STUDIES .1. STABILITY TO ACID AND ALKALI - SOLUBILITY - IONIZATION - COMPARISON WITH PTERIDINES [J].
ALBERT, A ;
BROWN, DJ .
JOURNAL OF THE CHEMICAL SOCIETY, 1954, (JUN) :2060-2071
[2]   CHARGE-TRANSFER AT PARTIALLY BLOCKED SURFACES - A MODEL FOR THE CASE OF MICROSCOPIC ACTIVE AND INACTIVE SITES [J].
AMATORE, C ;
SAVEANT, JM ;
TESSIER, D .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 147 (1-2) :39-51
[3]  
[Anonymous], Z ELECTROCHEM
[4]   Xanthine and hypoxanthine sensors based on xanthine oxidase immobilized in poly(mercapto-p-benzoquinone) film [J].
Arai, G ;
Takahashi, S ;
Yasumori, I .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1996, 410 (02) :173-179
[5]  
Bard A. J., 1980, ELECTROCHEMICAL METH
[6]   SCANNING ELECTRON-MICROSCOPY IN THE ANALYSIS OF THE ACTIVITY OF GRAPHITE-ELECTRODES [J].
BODALBHAI, L ;
BRAJTERTOTH, A .
ANALYTICA CHIMICA ACTA, 1990, 231 (02) :191-201
[7]  
BRAVO R, UNPUB
[8]  
Caraway WT, 1963, STANDARD METHODS CLI, V4, P239
[9]   Permselectivity sensitivity, and amperometric pH sensing at thioctic acid monolayer microelectrodes [J].
Cheng, Q ;
BrajterToth, A .
ANALYTICAL CHEMISTRY, 1996, 68 (23) :4180-4185
[10]   ELECTROCHEMICAL OXIDATION OF HYPOXANTHINE [J].
CONWAY, AC ;
GOYAL, RN ;
DRYHURST, G .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1981, 123 (02) :243-264