Robotic totally endoscopic coronary artery bypass: Program development and learning curve issues

被引:84
作者
Bonatti, J
Schachner, T
Bernecker, O
Chevtchik, O
Bonaros, N
Ott, H
Friedrich, G
Weidinger, F
Laufer, G
机构
[1] Univ Innsbruck Hosp, Dept Cardiac Surg, A-6020 Innsbruck, Austria
[2] Univ Innsbruck Hosp, Dept Cardiol, A-6020 Innsbruck, Austria
关键词
D O I
10.1016/j.jtcvs.2003.09.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The introduction of new procedures in heart surgery is a critical phase that includes learning curves and the risk of increased mortality or morbidity. Totally endoscopic coronary artery bypass grafting using robotic techniques represents such an innovative procedure. The aim of this report is to demonstrate the safe introduction of totally endoscopic coronary artery bypass grafting using a stepwise and modular approach. Methods: From June 2001 until December 2002, 50 procedures were performed using the da Vinci telemanipulator system. After baseline training the following procedure modules were carried out in a stepwise manner: robotically assisted endoscopic left internal thoracic artery harvesting and completion of the procedure as conventional coronary artery bypass grafting, minimally invasive direct coronary artery bypass, or off-pump coronary artery bypass (n = 19), robotically assisted suturing of left internal thoracic artery to left anterior descending anastomoses during conventional coronary artery bypass grafting (n = 15), totally endoscopic coronary artery bypass grafting on the arrested heart using remote access perfusion and aortic endocclusion coronary bypass grafting (n = 15). One patient was excluded intraoperatively from a robotic procedure due to pleural adhesions. Results: A significant learning curve was observed for left internal thoracic artery takedown time, y(min) = 181 - 39 X ln(x) (x = procedure number) (P < .001), and total operative time in totally endoscopic coronary artery bypass grafting, y(min) = 595 - 87 X ln(x) x = (procedure number) (P = .028). The conversion rate in totally endoscopic coronary artery bypass grafting was 2/15. Intensive care unit stay correlated significantly with total operative time (r = .427, P = .002). There was no hospital mortality. Conclusion: Totally endoscopic coronary artery bypass grafting can be safely implemented into a heart surgery program. Learning curves are steep for robotic left internal thoracic artery takedown and for performance of totally endoscopic coronary artery bypass grafting. Long operative times translate into prolonged intensive care unit stay in specific cases but not into increased mortality.
引用
收藏
页码:504 / 510
页数:7
相关论文
共 10 条
[1]  
Aybek T, 2000, HEART SURG FORUM, V3, P322
[2]   Clinical use of a computer-enhanced surgical robotic system for endoscopic coronary artery bypass crafting on the beating heart [J].
Boehm, DH ;
Reichenspurner, H ;
Detter, C ;
Arnold, M ;
Gulbins, H ;
Meiser, B ;
Reichart, B .
THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (04) :198-202
[3]   Initial prospective multicenter clinical trial of robotically-assisted coronary artery bypass grafting [J].
Damiano, RJ ;
Tabaie, HA ;
Mack, MJ ;
Edgerton, JR ;
Mullangi, C ;
Graper, WP ;
Prasad, SM .
ANNALS OF THORACIC SURGERY, 2001, 72 (04) :1263-1268
[4]   Computer-enhanced telemanipulation enables a variety of totally endoscopic cardiac procedures [J].
Dogan, S ;
Aybek, T ;
Khan, MF ;
Kessler, P ;
Mierdl, S ;
Kleine, P ;
Moritz, A ;
Wimmer-Greinecker, G .
THORACIC AND CARDIOVASCULAR SURGEON, 2002, 50 (05) :281-286
[5]   Totally endoscopic coronary artery bypass grafting on cardiopulmonary bypass with robotically enhanced telemanipulation: Report of forty-five cases [J].
Dogan, S ;
Aybek, T ;
Andressen, E ;
Byhahn, C ;
Mierdl, S ;
Westphal, K ;
Matheis, G ;
Moritz, A ;
Wimmer-Greinecker, G .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2002, 123 (06) :1125-1131
[6]   Total endoscopic computer enhanced coronary artery bypass grafting [J].
Falk, V ;
Diegeler, A ;
Walther, T ;
Banusch, J ;
Brucerius, J ;
Raumans, J ;
Autschbach, R ;
Mohr, FW .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 17 (01) :38-45
[7]   Robotic coronary artery surgery - the evolution of a new minimally invasive approach in coronary artery surgery [J].
Kappert, U ;
Cichon, R ;
Schneider, J ;
Gulielmos, V ;
Tugtekin, SM ;
Matschke, K ;
Schramm, I ;
Schueler, S .
THORACIC AND CARDIOVASCULAR SURGEON, 2000, 48 (04) :193-197
[8]   Endoscopic coronary artery bypass grafting with the aid of robotic assisted instruments [J].
Loulmet, D ;
Carpentier, A ;
d'Attellis, N ;
Berrebi, A ;
Cardon, C ;
Ponzio, O ;
Aupècle, B ;
Relland, JYM .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1999, 118 (01) :4-10
[9]   Computer-enhanced "robotic" cardiac surgery: Experience in 148 patients [J].
Mohr, FW ;
Falk, V ;
Diegeler, A ;
Walther, T ;
Gummert, JF ;
Bucerius, J ;
Jacobs, S ;
Autschbach, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2001, 121 (05) :842-853
[10]   Port-access coronary artery bypass with cardioplegic arrest: Acute and chronic canine studies [J].
Stevens, JH ;
Burdon, TA ;
Siegel, LC ;
Peters, WS ;
Pompili, MF ;
StGoar, FG ;
Berry, GJ ;
Ribakove, GH ;
Vierra, MA ;
Mitchell, RS ;
Toomasian, JM ;
Reitz, BA .
ANNALS OF THORACIC SURGERY, 1996, 62 (02) :435-440