In vitro long-term performance study of a near-infrared fluorescence affinity sensor for glucose monitoring

被引:65
作者
Ballerstadt, R
Polak, A
Beuhler, A
Frye, J
机构
[1] BioTex Inc, Houston, TX 77054 USA
[2] Motorola Inc, Northbrook, IL 60062 USA
关键词
diabetes; concanavalin A; dextran; sephadex; Alexa dye; fluorophore; regenerated cellulose acetate membrane;
D O I
10.1016/j.bios.2003.08.019
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The Iona-term in vitro performance of a fluorescence affinity sensor for transdermal blood glucose monitoring was investigated. Affinity binding of fluorescently labeled concanavalin A (ConA) was used in this application, as previously described by Ballerstadt and Schultz [Anal. Chem. 17 (2000) 4185-4192]. In this paper, the fluorescence emission of the sensor was extended to the near infrared (670 nm) using Alexa647(TM) as the fluorochrome conjugated to concanavalin A. Sensors were alternately exposed to glucose solutions having concentrations of 2.5 and 20 mM with a dwell time of 3 h. The optical output of the sensors was monitored over a 4-month period. The sensors showed an initial increase in fluorescence over the first 3-4 weeks before gradually decreasing, with an approximately linear drop of 25% per month. In order to understand the reasons for the decrease in fluorescence output, further experiments were conducted, including time-dependent membrane leakage tests. solubility tests of ConA, temperature-dependent activity tests of ConA, and fluorescence photo-bleaching tests. From these results. it became evident that the decrease in fluorescence was not due to denaturation of the ConA. The most likely cause was leakage of the fluorescently labeled ConA through the interface between the outer sealant and the membrane. This problem is considered to be solvable and future publications will address this issue. Extrapolation of the experimental data suggests that a leak-proof sensor would be remarkably stable with a fluorescence decrease of only 15% over a 1-year period. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:905 / 914
页数:10
相关论文
共 29 条
  • [1] ABEL P, 1984, BIOMED BIOCHIM ACTA, V43, P577
  • [2] Arnold M.A., 1996, HDB CLIN LAB AUTOMAT, P631
  • [3] SUITABILITY OF AQUEOUS DISPERSIONS OF DEXTRAN AND CONCANAVALIN-A FOR GLUCOSE SENSING IN DIFFERENT VARIANTS OF THE AFFINITY SENSOR
    BALLERSTADT, R
    EHWALD, R
    [J]. BIOSENSORS & BIOELECTRONICS, 1994, 9 (08) : 557 - 567
  • [4] Competitive-binding assay method based on fluorescence quenching of ligands held in close proximity by a multivalent receptor
    Ballerstadt, R
    Schultz, JS
    [J]. ANALYTICA CHIMICA ACTA, 1997, 345 (1-3) : 203 - 212
  • [5] A fluorescence affinity hollow fiber sensor for continuous transdermal glucose monitoring
    Ballerstadt, R
    Schultz, JS
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (17) : 4185 - 4192
  • [6] A CONCANAVALIN A-COATED PIEZOELECTRIC CRYSTAL BIOSENSOR
    BARNES, C
    DSILVA, C
    JONES, JP
    LEWIS, TJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1991, 3 (04) : 295 - 304
  • [7] Recording of subcutaneous glucose dynamics by a viscometric affinity sensor
    Beyer, U
    Schäfer, D
    Thomas, A
    Aulich, H
    Haueter, U
    Reihl, B
    Ehwald, R
    [J]. DIABETOLOGIA, 2001, 44 (04) : 416 - 423
  • [8] BRUMFIELD A, 1998, P WORLD C BIOS BERL
  • [9] CHOWDURY TK, 1925, CONCANAVALIN A
  • [10] CUNNINGHAM BA, 1972, BIOCHEMISTRY-US, V11, P3233, DOI 10.1021/bi00767a016