Each lumen is a potential source of central venous catheter-related bloodstream infection

被引:44
作者
Dobbins, BM
Catton, JA
Kite, P
McMahon, MJ
Wilcox, MH [1 ]
机构
[1] Univ Leeds, Gen Infirm, Dept Microbiol, Leeds LS1 3EX, W Yorkshire, England
[2] Gen Infirm, Acad Dept Surg, Leeds LS1 3EX, W Yorkshire, England
[3] Univ Leeds, Leeds, W Yorkshire, England
关键词
central venous catheter-related infection; multiple lumen;
D O I
10.1097/01.CCM.0000063257.04633.AE
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective. To determine the relative rates of microbial colonization of individual lumens in triple-lumen central venous catheters (CVCs) and calculate the chance, of detecting catheter-related blood stream infection (CRBSI) if only one lumen is sampled. Design: Prospective evaluation of CVCs from suspected and nonsuspected CRBSI cases. Setting. University teaching hospital. Patients: Triple-lumen CVCs from 50 cases of suspected CRBSI (a raised peripheral white blood cell count, temperature >37degreesC, and/or local signs of infection at the catheter skin entry site) were evaluated. For comparison, 50 triple-lumen CVCs routinely removed at the end of use were evaluated. Measurements: In both groups, peripheral blood cultures were taken before CVC removal. After CVC removal, each lumen was sampled in vitro using the endoluminal brush, and the tip was then cultured using the Maki roll technique. Main Results. CVCs causing CRBSI had significant microbial colonization in one, two, or three lumens in ten (40%), ten (40%), or five (20%) cases, respectively. Overall, random sampling of only one lumen in CVCs causing CRBSI had a 60% chance of detecting significant colonization. Conclusions. If only one CVC lumen is sampled, a negative result does not reliably rule out infection. Each lumen of multiple-lumen CVCs should be considered as a potential source of CRBSI.
引用
收藏
页码:1688 / 1690
页数:3
相关论文
共 10 条
[1]  
[Anonymous], 2001, J HOSP INFECT S, V47, pS47
[2]   Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures [J].
Blot, F ;
Nitenberg, G ;
Chachaty, E ;
Raynard, B ;
Germann, N ;
Antoun, S ;
Laplanche, A ;
Brun-Buisson, C ;
Tancrede, C .
LANCET, 1999, 354 (9184) :1071-1077
[3]   Diagnosis of central venous catheter related sepsis - a critical look inside [J].
Dobbins, BM ;
Kite, P ;
Wilcox, MH .
JOURNAL OF CLINICAL PATHOLOGY, 1999, 52 (03) :165-172
[4]   Evaluation of a novel endoluminal brush method for in situ diagnosis of catheter related sepsis [J].
Kite, P ;
Dobbins, BM ;
Wilcox, MH ;
Fawley, WN ;
Kindon, AJL ;
Thomas, D ;
Tighe, MJ ;
McMahon, MJ .
JOURNAL OF CLINICAL PATHOLOGY, 1997, 50 (04) :278-282
[5]   Rapid diagnosis of central-venous-catheter-related bloodstream infection without catheter removal [J].
Kite, P ;
Dobbins, BM ;
Wilcox, MH ;
McMahon, MJ .
LANCET, 1999, 354 (9189) :1504-1507
[6]   SEMIQUANTITATIVE CULTURE METHOD FOR IDENTIFYING INTRAVENOUS-CATHETER-RELATED INFECTION [J].
MAKI, DG ;
WEISE, CE ;
SARAFIN, HW .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 296 (23) :1305-1309
[7]  
Mermel LA, 2001, CLIN INFECT DIS, V32, P1249, DOI 10.1086/320001
[8]  
Pearson ML, 1996, INFECT CONT HOSP EP, V17, P438
[9]  
*PUBL HLTH LAB SER, 2002, SURV HOSP ACQ BACT E
[10]   CATHETER COMPLICATIONS IN TOTAL PARENTERAL NUTRITION - PROSPECTIVE STUDY OF 200 CONSECUTIVE PATIENTS [J].
RYAN, JA ;
ABEL, RM ;
ABBOTT, WM ;
HOPKINS, CC ;
FISCHER, JL ;
CHESNEY, TM ;
COLLEY, R ;
PHILLIPS, K .
NEW ENGLAND JOURNAL OF MEDICINE, 1974, 290 (14) :757-761