Investigation of a single-basin solar still with deep basins

被引:75
作者
Aboul-Enein, S [1 ]
El-Sebaii, AA [1 ]
El-Bialy, E [1 ]
机构
[1] Tanta Univ, Fac Sci, Dept Phys, Tanta, Egypt
关键词
solar still; productivity; heat transfer coefficients;
D O I
10.1016/S0960-1481(98)00081-0
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A single basin solar still (SBSS) is designed and constructed. A simple transient mathematical model is presented for the still. It is based on analytical solution of the energy-balance equations for different parts of the still. Analytical expressions for temperatures of different components have been obtained. The thermal performance of the still has been investigated both experimentally and theoretically. Good agreement between experimental and theoretical results is observed. The influence of cover slope on the daily productivity of the still was investigated. Effect of heat capacity of basin water on the daylight and overnight productivities was also studied. It is inferred that, the productivity of the still decreases with an increase of heat capacity of basin water during daylight and the reverse is the case overnight. The optimum tilt angles of the still cover were found to be 10 and 50 degrees during the summer and winter seasons, respectively, in Tanta (30 degrees 47'N). The daily efficiency of the still is about 27%. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:299 / 305
页数:7
相关论文
共 23 条
[1]   SCOPE AND DEVELOPMENT OF SOLAR STILLS FOR WATER DESALINATION IN INDIA [J].
AHMED, SY ;
GOMKALE, SD ;
DATTA, RL ;
DATAR, DS .
DESALINATION, 1968, 5 (01) :64-&
[2]   ENHANCING OF SOLAR-STILL PRODUCTIVITY USING VACUUM TECHNOLOGY [J].
ALHUSSAINI, H ;
SMITH, IK .
ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (11) :1047-1051
[3]  
Duffie JA., 1980, Solar engineering of thermal processes
[4]  
Dunkle R.V., 1961, P INT C HEAT TRANSFE, P895, DOI DOI 10.4236/SGRE.2013.48055
[5]  
Dzhubalieva P.A., 1965, APPL SOLAR ENERGY, V1, P37
[6]  
El-Bassuoni A.-M. A., 1986, Solar & Wind Technology, V3, P189, DOI 10.1016/0741-983X(86)90032-9
[7]   EFFECT OF ADDING A PASSIVE CONDENSER ON SOLAR-STILL PERFORMANCE [J].
FATH, HES ;
ELSHERBINY, SM .
ENERGY CONVERSION AND MANAGEMENT, 1993, 34 (01) :63-72
[8]   EFFECT OF CLIMATIC, OPERATIONAL AND DESIGN PARAMETERS ON YEAR ROUND PERFORMANCE OF SINGLE-SLOPED AND DOUBLE-SLOPED SOLAR-STILL UNDER INDIAN ARID ZONE CONDITIONS [J].
GARG, HP ;
MANN, HS .
SOLAR ENERGY, 1976, 18 (02) :159-164
[9]   EFFECT OF HEAT-CAPACITY ON THE PERFORMANCE OF SOLAR-STILL WITH WATER-FLOW OVER THE GLASS COVER [J].
LAWRENCE, SA ;
GUPTA, SP ;
TIWARI, GN .
ENERGY CONVERSION AND MANAGEMENT, 1990, 30 (03) :277-285
[10]   AN IMPROVED SOLAR-STILL - THE WICK-BASIN TYPE [J].
MINASIAN, AN ;
ALKARAGHOULI, AA .
ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (03) :213-217