Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater

被引:142
作者
Morrison, GL [1 ]
Budihardjo, I
Behnia, M
机构
[1] Univ New S Wales, Sch Mech & Mfg Engn, Sydney, NSW 2052, Australia
[2] Univ Sydney, Sydney, NSW 2006, Australia
关键词
natural circulation; water-in-glass; evacuated tube;
D O I
10.1016/j.solener.2004.09.005
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper evaluates the characteristics of water-in-glass evacuated tube solar water heaters including assessment of the circulation rate through single ended tubes. A numerical model of the heat transfer and fluid flow inside a single-ended evacuated tube has been developed assuming no interaction between adjacent tubes in the collector array. Flow measurement using Particle Image Velocimetry (PIV) has been undertaken to validate the numerical model. The experimental rig consists of a single full-scale tube coupled to a storage tank. A non-dimensional correlation has been developed of the circulation rate through a single evacuated tube mounted at 45degrees inclination over a diffuse reflector. Simulation results show that the natural convection flow rate in the tube is high enough to disturb the tank's stratification and that the tank temperature strongly affects the circulation flow rate through the tubes. Circumferential heat distribution was found to be an important parameter influencing the flow structure and circulation rate through the tube, hence a separate correlation needs to be developed if a concentrating reflector is incorporated into the collector. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:257 / 267
页数:11
相关论文
共 23 条
[1]  
[Anonymous], 1994, 94592 ISO
[2]   TRANSIENT AND STEADY BEHAVIOR OF AN OPEN, SYMMETRICALLY-HEATED, FREE-CONVECTION LOOP [J].
BAU, HH ;
TORRANCE, KE .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1981, 24 (04) :597-609
[3]  
Budihardjo I., 2002, P ANZSES ANN C NEWC
[4]   A DEVICE FOR MEASURING THE ANGULAR-DISTRIBUTION OF INCIDENT RADIATION ON TUBULAR SOLAR COLLECTORS [J].
CABANILLAS, RE ;
ESTRADA, CA ;
AVILA, F .
RENEWABLE ENERGY, 1995, 6 (07) :843-847
[5]   Numerical analysis of a symmetrically heated vertical channel with obstruction [J].
Cammarata, G ;
Desrayaud, G ;
Fichera, A ;
Fischetti, C .
HEAT AND MASS TRANSFER, 2000, 36 (06) :481-486
[6]   A NUMERICAL STUDY OF TWO-DIMENSIONAL LAMINAR NATURAL-CONVECTION IN SHALLOW OPEN CAVITIES [J].
CHAN, YL ;
TIEN, CL .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1985, 28 (03) :603-612
[7]  
*CHIN IND, 2001, NEW REN SOURC EN CHI
[8]  
*FLUENT INC, 2001, REL FLUENT 6 0
[9]   Experimental study of flow rates through inclined open thermosyphons [J].
Gaa, FO ;
Behnia, M ;
Morrison, GL .
SOLAR ENERGY, 1996, 57 (05) :401-408
[10]   THERMOSIPHON CIRCULATION IN SOLAR WATER HEATERS INCORPORATING EVACUATED TUBULAR COLLECTORS AND A NOVEL WATER-IN-GLASS MANIFOLD [J].
HARDING, GL ;
YIN, ZQ .
SOLAR ENERGY, 1985, 34 (01) :13-18