Quantitative myocardial perfusion with stress dual-energy CT: iodine concentration differences between normal and ischemic or necrotic myocardium. Initial experience

被引:49
作者
Delgado Sanchez-Gracian, Carlos [1 ]
Oca Pernas, Roque [1 ]
Trinidad Lopez, Carmen [1 ]
Santos Armentia, Eloisa [1 ]
Vaamonde Liste, Antonio [2 ,3 ]
Vazquez Caamano, Maria [1 ]
Tardaguila de la Fuente, Gonzalo [1 ]
机构
[1] Povisa Hosp, Dept Radiol, Vigo 36211, Pontevedra, Spain
[2] Univ Vigo, Vigo, Pontevedra, Spain
[3] Povisa Hosp, Vigo, Pontevedra, Spain
关键词
Myocardial perfusion imaging; Tomography; X-ray computed; Magnetic resonance imaging; Iodine maps; CORONARY-ARTERY STENOSIS; OPTIMAL MEDICAL THERAPY; COMPUTED-TOMOGRAPHY; DIAGNOSTIC PERFORMANCE; ANGIOGRAPHY; ACCURACY; QUANTIFICATION; REVASCULARIZATION; DISEASE;
D O I
10.1007/s00330-015-4128-y
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
To determine whether the quantification of iodine with stress dual-energy computed tomography (DECT-S) allows for the discrimination between a normal and an ischemic or necrotic myocardium using magnetic resonance (MR) as a reference. This retrospective study was approved by the institutional review board, with waiver of informed consent. Thirty-six cardiac MR and DECT-S images from patients with suspected coronary artery disease were evaluated. Perfusion defects were visually determined, and myocardial iodine concentration was calculated by two observers using DECT colour-coded iodine maps. Iodine concentration differences were calculated using parametric tests. Receiver operating characteristic (ROC) curve analysis was conducted to estimate the optimal iodine concentration threshold for discriminating pathologic myocardium. In total, 576 cardiac segments were evaluated. There were differences in mean iodine concentration (p < 0.001) between normal (2.56 +/- 0.66 mg/mL), ischemic (1.98 +/- 0.36 mg/dL) and infarcted segments (1.35 +/- 0.57 mg/mL). A myocardium iodine concentration of 2.1 mg/mL represented the optimal threshold to discriminate between normal and pathologic myocardium (sensitivity 75 %, specificity 73.6 %, area under the curve 0.806). Excellent agreement was found in measured myocardium iodine concentration (intraclass correlation coefficient 0.814). Cardiac DECT-S with iodine quantification may be useful to differentiate healthy and ischemic or necrotic myocardium. aEuro cent DECT-S allows for determination of myocardial iodine concentration as a quantitative perfusion parameter. aEuro cent A high interobserver correlation exists in measuring myocardial iodine concentration with DECT-S. aEuro cent Myocardial iodine concentration may be useful in the assessment of patients with CAD.
引用
收藏
页码:3199 / 3207
页数:9
相关论文
共 31 条
[1]
Detection of Hemodynamically Significant Coronary Artery Stenosis: Incremental Diagnostic Value of Dynamic CT-based Myocardial Perfusion Imaging [J].
Bamberg, Fabian ;
Becker, Alexander ;
Schwarz, Florian ;
Marcus, Roy P. ;
Greif, Martin ;
von Ziegler, Franz ;
Blankstein, Ron ;
Hoffmann, Udo ;
Sommer, Wieland H. ;
Hoffmann, Verena S. ;
Johnson, Thorsten R. C. ;
Becker, Hans-Christoph R. ;
Wintersperger, Bernd J. ;
Reiser, Maximilian F. ;
Nikolaou, Konstantin .
RADIOLOGY, 2011, 260 (03) :689-698
[2]
Adenosine-Stress Dynamic Myocardial CT Perfusion Imaging Initial Clinical Experience [J].
Bastarrika, Gorka ;
Ramos-Duran, Luis ;
Rosenblum, Michael A. ;
Kang, Doo Kyoung ;
Rowe, Garrett W. ;
Schoepf, U. Joseph .
INVESTIGATIVE RADIOLOGY, 2010, 45 (06) :306-313
[3]
Incremental value of an integrated adenosine stress-rest MDCT perfusion protocol for detection of obstructive coronary artery disease [J].
Bettencourt, Nuno ;
Rocha, Joao ;
Ferreira, Nuno ;
Pires-Morais, Gustavo ;
Carvalho, Monica ;
Leite, Daniel ;
Melica, Bruno ;
Santos, Lino ;
Rodrigues, Alberto ;
Braga, Pedro ;
Teixeira, Madalena ;
Simoes, Lino ;
Leite-Moreira, Adelino ;
Cardoso, Silva ;
Nagel, Eike ;
Gama, Vasco .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2011, 5 (06) :392-405
[4]
Adenosine-Induced Stress Myocardial Perfusion Imaging Using Dual-Source Cardiac Computed Tomography [J].
Blankstein, Ron ;
Shturman, Leon D. ;
Rogers, Ian S. ;
Rocha-Filho, Jose A. ;
Okada, David R. ;
Sarwar, Ammar ;
Soni, Anand V. ;
Bezerra, Hiram ;
Ghoshhajra, Brian B. ;
Petranovic, Milena ;
Loureiro, Ricardo ;
Feuchtner, Gudrun ;
Gewirtz, Henry ;
Hoffmann, Udo ;
Mamuya, Wilfred S. ;
Brady, Thomas J. ;
Cury, Ricardo C. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 54 (12) :1072-1084
[5]
Optimal medical therapy with or without PCI for stable coronary disease [J].
Boden, William E. ;
O'Rourke, Robert A. ;
Teo, Koon K. ;
Hartigan, Pamela M. ;
Maron, David J. ;
Kostuk, William J. ;
Knudtson, Merril ;
Dada, Marcin ;
Casperson, Paul ;
Harris, Crystal L. ;
Chaitman, Bernard R. ;
Shaw, Leslee ;
Gosselin, Gilbert ;
Nawaz, Shah ;
Title, Lawrence M. ;
Gau, Gerald ;
Blaustein, Alvin S. ;
Booth, David C. ;
Bates, Eric R. ;
Spertus, John A. ;
Berman, Daniel S. ;
Mancini, G. B. John ;
Weintraub, William S. ;
Boden, W. ;
O'Rourke, R. ;
Teo, K. ;
Hartigan, P. ;
Weintraub, W. ;
Maron, D. ;
Mancini, J. ;
Weintraub, W. ;
Boden, W. ;
O'Rourke, R. ;
Teo, K. ;
Hartigan, P. ;
Knudtson, M. ;
Maron, D. ;
Bates, E. ;
Blaustein, A. ;
Booth, D. ;
Carere, R. ;
Ellis, S. ;
Gosselin, G. ;
Gau, G. ;
Jacobs, A. ;
King, S., III ;
Kostuk, W. ;
Harris, C. ;
Spertus, J. ;
Peduzzi, P. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (15) :1503-1516
[6]
Towards complete and accurate reporting of studies of diagnostic accuracy: The STARD initiative [J].
Bossuyt, PM ;
Reitsma, JB ;
Bruns, DE ;
Gatsonis, CA ;
Glasziou, PP ;
Irwig, LM ;
Lijmer, JG ;
Moher, D ;
Rennie, D ;
de Vet, HCW .
RADIOLOGY, 2003, 226 (01) :24-28
[7]
Diagnostic Performance of 64-Multidetector Row Coronary Computed Tomographic Angiography for Evaluation of Coronary Artery Stenosis in Individuals Without Known Coronary Artery Disease [J].
Budoff, Matthew J. ;
Dowe, David ;
Jollis, James G. ;
Gitter, Michael ;
Sutherland, John ;
Halamert, Edward ;
Scherer, Markus ;
Bellinger, Raye ;
Martin, Arthur ;
Benton, Robert ;
Delago, Augustin ;
Min, James K. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (21) :1724-1732
[8]
Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses [J].
Chandarana, Hersh ;
Megibow, Alec J. ;
Cohen, Benjamin A. ;
Srinivasan, Ramya ;
Kim, Danny ;
Leidecker, Christianne ;
Macari, Michael .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) :W693-W700
[9]
Multisection CT Protocols: Sex- and Age-specific Conversion Factors Used to Determine Effective Dose from Dose-Length Product [J].
Deak, Paul D. ;
Smal, Yulia ;
Kalender, Willi A. .
RADIOLOGY, 2010, 257 (01) :158-166
[10]
Myocardial Ischemia Evaluation With Dual-source Computed Tomography: Comparison With Magnetic Resonance Imaging [J].
Delgado, Carlos ;
Vazquez, Maria ;
Oca, Roque ;
Vilar, Manuel ;
Trinidad, Carmen ;
Sanmartin, Marcelo .
REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (11) :864-870