Fast photomultiplier tube gating system for photon counting applications

被引:30
作者
Creasey, DJ [1 ]
Halford-Maw, PA [1 ]
Heard, DE [1 ]
Spence, JE [1 ]
Whitaker, BJ [1 ]
机构
[1] Univ Leeds, Sch Chem, Leeds LS2 9JT, W Yorkshire, England
关键词
D O I
10.1063/1.1149252
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A normally "on'' linear-focused 14-stage end-window photomultiplier tube (PMT) (Electron Tubes Limited 9893Q/100B), designed for fast photon counting, has been gated through control of the voltage applied to the first dynode. The gating circuit reduces the gain of the PMT during a laser pulse, in order to discriminate against the detection of scattered light, and then increases the gain promptly to observe extremely low levels of laser-induced fluorescence (LIF). An extinction factor for the laser scattered photons of > 10(5) was observed, and has enabled count rates for photons due to LIF as low as 1 Hz to be measured for a laser pulse-repetition frequency of 7 kHz. The rise of the PMT gain is monitored directly by observation of the fluorescence using time-resolved photon counting, and the PMT turn-on time is 30 ns. No significant distortion of the temporal profile of the fluorescence was observed during PMT turn-on. The system, which can also be operated in ungated mode, is rugged and reliable, and has been employed outdoors during atmospheric field measurements of the hydroxyl radical using LIF. The gating circuit is suitable for the rejection of laser scattered light in applications with extremely low levels of fluorescence on the submicrosecond timescale. (C) 1998 American Institute of Physics. [S0034-6748(98)02212-6].
引用
收藏
页码:4068 / 4073
页数:6
相关论文
共 20 条
  • [1] NORMALLY ON FAST-GAIN SWITCH FOR PHOTOMULTIPLIER TUBES
    BALLARD, SG
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1983, 54 (11) : 1473 - 1475
  • [2] GRID-GATED PHOTOMULTIPLIER PHOTOMETER WITH SUB-NANOSECOND TIME RESPONSE
    BARISAS, BG
    LEUTHER, MD
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1980, 51 (01) : 74 - 78
  • [3] GATED PHOTOMULTIPLIERS WITH GAAS CATHODES FOR A THOMSON-SCATTERING DIAGNOSTIC - GATE CIRCUIT AND CALIBRATION METHOD
    BARTH, CJ
    KOENEN, FTM
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1989, 22 (03): : 178 - 180
  • [4] Implementation and initial deployment of a field instrument for measurement of OH and HO2 in the troposphere by laser-induced fluorescence
    Creasey, DJ
    HalfordMaw, PA
    Heard, DE
    Pilling, MJ
    Whitaker, BJ
    [J]. JOURNAL OF THE CHEMICAL SOCIETY-FARADAY TRANSACTIONS, 1997, 93 (16): : 2907 - 2913
  • [5] Visualisation of a supersonic free-jet expansion using laser-induced fluorescence spectroscopy: Application to the measurement of rate constants at ultralow temperatures
    Creasey, DJ
    Heard, DE
    Pilling, MJ
    Whitaker, BJ
    Berzins, M
    Fairlie, R
    [J]. APPLIED PHYSICS B-LASERS AND OPTICS, 1997, 65 (03): : 375 - 391
  • [6] CREASEY DJ, 1998, THESIS U LEEDS
  • [7] CREASEY DJ, UNPUB
  • [8] A METHOD OF APPLYING AN AVALANCHE TRANSISTOR GENERATED 70 NS GATING PULSE TO A FOCUSED PHOTOMULTIPLIER
    ELPHICK, BL
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (11): : 953 - &
  • [9] HEAL MR, 1995, J ATMOS SCI, V52, P3428, DOI 10.1175/1520-0469(1995)052<3428:OTDAVO>2.0.CO
  • [10] 2