The START Trial - measurements in semi-anatomical breast and chest wall phantoms

被引:18
作者
Venables, K
Winfield, E
Deighton, A
Aird, E
Hoskin, P
机构
[1] Mt Vernon Hosp, Northwood HA6 2RN, Middx, England
[2] Mt Vernon Hosp, Dept Phys, Northwood HA6 2RN, Middx, England
关键词
D O I
10.1088/0031-9155/46/7/314
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper describes dosimetry measurements performed prior to departments entering patients into the START Trial, a breast fractionation trial, Absolute and relative doses were measured in semi-anatomical breast and chest wall phantoms., as part of a quality assurance programme visit. Doses were measured using an ionization chamber and the resulting distributions were compared with those calculated by the department. The mean ratio of measured to calculated dose at the START reference point was found to be 0.981 for the breast phantom and 0.978 for the chest wall phantom. This average measured dose was significantly less than the prescribed dose (p < 0.001). Differences were found between 2D and 3D planning systems and for departments using cobalt 60 beams. A number of departments had deviations of greater than 4%, which was the tolerance applied for this trial. It is essential for dose measurements of this type to be performed for randomized clinical trials involving radiotherapy, particularly where dose fractionation regimes are being compared.
引用
收藏
页码:1937 / 1948
页数:12
相关论文
共 10 条
[1]   Tangential breast irradiation: a multi-centric intercomparison of dose using a mailed phantom and thermoluminescent dosimetry [J].
Davis, JB ;
Miltchev, V .
RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) :65-68
[2]   Three-dimensional dose distribution of tangential breast irradiation: results of a multicentre phantom dosimetry study [J].
Delancy, G ;
Beckham, W ;
Veness, M ;
Ahern, V ;
Back, M ;
Boyages, J ;
Fox, C ;
Graham, P ;
Jacob, G ;
Lonergan, D ;
Morgan, G ;
Pendlebury, S ;
Yuile, P .
RADIOTHERAPY AND ONCOLOGY, 2000, 57 (01) :61-68
[3]  
*INT COMM RAD UN M, 1993, 50 ICRU, P20
[4]  
*INT COMM RAD UN M, 1978, 29 ICRU, P5
[5]   CODE OF PRACTICE FOR HIGH-ENERGY PHOTON THERAPY DOSIMETRY BASED ON THE NPL ABSORBED DOSE CALIBRATION SERVICE [J].
LILLICRAP, SC ;
OWEN, B ;
WILLIAMS, JR ;
WILLIAMS, PC .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1355-1360
[6]   DEPTH DOSE IN SKIN FOR OBLIQUELY INCIDENT CO-60 RADIATION [J].
ORTON, CG ;
SEIBERT, JB .
BRITISH JOURNAL OF RADIOLOGY, 1972, 45 (532) :271-+
[7]  
*STAND BREAST RAD, 1999, CLIN ONCOL, V11, P145
[8]   SUPERFICIAL DOSES IN TREATMENT OF BREAST WITH TANGENTIAL FIELDS USING 4 MV X-RAYS [J].
SVENSSON, GK ;
BJARNGARD, BE ;
CHEN, GTY ;
WEICHSELBAUM, RR .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1977, 2 (7-8) :705-710
[9]   3-DIMENSIONAL DOSE DISTRIBUTION OF TANGENTIAL BREAST TREATMENT - A NATIONAL DOSIMETRY INTERCOMPARISON [J].
VANBREE, NAM ;
VANBATTUM, LJ ;
HUIZENGA, H ;
MIJNHEER, BJ .
RADIOTHERAPY AND ONCOLOGY, 1991, 22 (04) :252-260
[10]   Breast radiotherapy phantom design for the START trial [J].
Venables, K ;
Winfield, E ;
Deighton, A ;
Aird, E ;
Hoskin, P .
BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (876) :1313-1316