Background: Scoliosis is a complex three-dimensional deformity with limited treatment options. Current treatments present potential problems that may be addressed with use of fusionless techniques for the correction of scoliosis. However, there are few data comparing the efficacy of different fusionless implant strategies in controlling scoliosis or on the integrity of rigid compared with flexible devices in an in vivo setting over time. The objective of this study was to compare the efficacy and integrity of rigid and flexible anterior thoracic tethers used to treat experimental scoliosis. Methods: Experimental scoliosis was created in twenty-four Spanish Cross-X female goats and was subsequently treated with either anterior shape memory alloy staples or anterior ligament tethers attached to bone anchors. Serial radiographs were analyzed to determine the efficacy of the implants in controlling scoliosis progression as well as the integrity of the implants at study completion. After the goats were killed, the implants were analyzed with use of three quantitative indices of implant integrity and implant pullout testing. Results: Over the treatment period, scoliosis progressed from 77.3 degrees to 94.3 degrees in the goats treated with staples and was corrected from 73.4 degrees to 69.9 degrees in the goats treated with bone anchors, with loosening of eighteen of forty-two staples (two of the eighteen dislodged) and evidence of drift in two of forty-nine anchors. Histologic sections revealed a consistent halo of fibrous tissue around the staple tines but well-fixed bone anchors at all sites. Pullout testing demonstrated that bone anchors had greater strength than staples initially and at the study completion, with an increase in bone anchor fixation over the course of the study. Conclusions: In this scoliosis model, the flexible ligament tethers attached to bone anchors demonstrated greater efficacy and integrity than the more rigid shape memory alloy staples. Clinical Relevance: Fusionless scoliosis surgery offers many theoretical advantages over instrumented arthrodesis. Improvements in fusionless implant design, with a specific focus on optimizing the fixation to bone and maximizing the tethering effect, may lead to better control of idiopathic scoliosis with lower rates of device loosening and failure.
引用
收藏
页码:2038 / 2051
页数:14
相关论文
共 52 条
[1]
Early weaning might reduce the psychological strain of Boston bracing: a study of 136 patients with adolescent idiopathic scoliosis at 3.5 years after termination of brace treatment [J].
Andersen, MO ;
Andersen, GR ;
Thomsen, K ;
Christensen, SB .
JOURNAL OF PEDIATRIC ORTHOPAEDICS-PART B, 2002, 11 (02) :96-99
[2]
PSYCHOLOGICAL AND PSYCHIATRIC INVESTIGATION OF ADJUSTMENT OF FEMALE SCOLIOSIS PATIENTS [J].
BENGTSSON, G ;
FALLSTROM, K ;
JANSSON, B ;
NACHEMSON, A .
ACTA PSYCHIATRICA SCANDINAVICA, 1974, 50 (01) :50-59
[3]
An innovative technique of vertebral body stapling for the treatment of patients with adolescent idiopathic scoliosis: A feasibility, safety, and utility study [J].
Betz, RR ;
Kim, J ;
D'Andrea, LP ;
Mulcahey, MJ ;
Balsara, RK ;
Clements, DH .
SPINE, 2003, 28 (20) :S255-S265
[4]
Porous-coated metal-backed patellar components in total knee replacement - A postmortem retrieval analysis [J].
Bloebaum, RD ;
Bachus, KN ;
Jensen, JW ;
Scott, DF ;
Hofmann, AA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (04) :518-528
[5]
BLOEBAUM RD, 1989, J HISTOTECHNOL, V12, P307
[6]
BLOEBAUM RD, 1991, CLIN ORTHOP RELAT R, P97
[7]
Fusionless scoliosis correction using a shape memory alloy staple in the anterior thoracic spine of the immature goat [J].
Braun, JT ;
Ogilvie, JW ;
Akyuz, E ;
Brodke, DS ;
Bachus, KN .
SPINE, 2004, 29 (18) :1980-1989
[8]
Experimental scoliosis in an immature goat model: A method that creates idiopathic-type deformity with minimal violation of the spinal elements along the curve [J].
Braun, JT ;
Ogilvie, JW ;
Akyuz, E ;
Brodke, DS ;
Bachus, KN ;
Stefko, RM .
SPINE, 2003, 28 (19) :2198-2203
[9]
BRAUN JT, 2002, ANN M SCOL RES SOC S
[10]
BRAUN JT, 2004, ANN M SCOL RES SOC S