The importance of radiometer angular response for ultraviolet phototherapy dosimetry

被引:25
作者
Martin, CJ
Currie, GD
Pye, SD
机构
[1] W Glasgow Hosp Univ NHS Trust, Dept Clin Phys & Bioengn, Glasgow G12 8SQ, Lanark, Scotland
[2] Univ Edinburgh, Western Gen Hosp, Dept Med Phys & Med Engn, Edinburgh EH4 2XU, Midlothian, Scotland
关键词
D O I
10.1088/0031-9155/44/4/003
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The influence of the angular response of radiometer probes on measurements of irradiance in ultraviolet phototherapy has been studied. Irradiance measurements were made using nine ultraviolet (UV) radiometers employed by phototherapy centres in Scotland and Northern Ireland, and compared with measurements made using two spectroradiometers. The light sources used were WE TL01 fluorescent lamps, arranged in different geometries. Irradiances within TL01 whole body treatment cabinets were assessed based on a comparison with one of the spectroradiometers. The results show variations of 50% in cabinet irradiance measurements made by different radiometers, even when they were calibrated using the same source geometry and spectroradiometer. Differences in radiometer probe design and construction lead to an under- or over-response at angles of incidence greater than zero. Angular responses of different probes were assessed using banks of fluorescent lamps. The differences found are large enough to account for the variations in measurements of cabinet irradiance. The variations in irradiance measurements are significant in terms of planning and monitoring patient exposure during TL01 phototherapy. Accurate dosimetry can only be achieved if radiometer probes have a good cosine response and recommendations are made for better calibration techniques.
引用
收藏
页码:843 / 855
页数:13
相关论文
共 7 条
[1]  
ANGELO R, 1998, COMMUNICATION
[2]   An appraisal of narrowband (TL-01) UVB phototherapy. British Photodermatology Group Workshop Report (April 1996) [J].
Bilsland, D ;
Dawe, R ;
Diffey, BL ;
Farr, P ;
Ferguson, J ;
George, S ;
Gibbs, NK ;
Green, C ;
McGregor, J ;
VanWeelden, H ;
Wainwright, NJ ;
Young, AR .
BRITISH JOURNAL OF DERMATOLOGY, 1997, 137 (03) :327-330
[3]  
DIFFEY BL, 1982, 76 IPEM
[4]   ULTRAVIOLET-RADIATION IN THE TREATMENT OF SKIN-DISEASE [J].
GREEN, C ;
DIFFEY, BL ;
HAWK, JLM .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (01) :1-20
[5]   An insight into the contributions of self-shielding and lamp reflectors to patient exposure in phototherapy units [J].
Langmack, KA .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (01) :207-214
[6]  
Stobbart D., 1980, Clinical Physics and Physiological Measurement, V1, P267, DOI 10.1088/0143-0815/1/4/003
[7]  
VANWEELDEN H, 1988, BRIT J DERMATOL, V119, P11