Objectives: We compared the annulus diameters measured by transthoracic echocardiography (TTE), transesophageal echocardiography (TEE), and dual-source computed tomography (DSCT) before transcatheter aortic valve implantation (TAVI). Background: In TAVI correct evaluation of the aortic annulus is mandatory to choose the correct prosthesis type and size and to prevent complications. There is no gold standard for the assessment of aortic annulus diameters. Methods: Preoperative assessment of the aortic annulus with TTE, TEE, and DSCT was performed in 187 consecutive patients referred for TAVI between June 2007 and May 2009. Results: The mean aortic annuli were 22.6 +/- 2.0 mm measured with DSCT, 22.3 +/- 2.5 mm with TTE, and 22.9 +/- 2.2 mm with TEE. Despite a strong correlation between the measurement techniques, relevant statistical spread occurred with differences up to 3 mm in all measurement methods. Inter-and intraobserver variability was good for TEE and less satisfactory for DSCT measurements. TEE measurements taken as decisive parameter for the implantation changed the implantation strategy in 15.5% of patients and did not show an increased rate of procedural complications. Conclusion: Despite a strong correlation, the measurement techniques for the aortic annulus show relevant statistical spread, consequently one measurement technique cannot definitely predict another. TEE measurements show a more satisfactory intra-and interobserver variability than DSCT. Taking TEE annulus measurements as decisive parameter for the implantation has an impact on the implantation strategy and is safe with a low rate of procedural complications. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1009 / 1019
页数:11
相关论文
共 30 条
[1]   Accuracy of transesophageal echocardiography in preoperative determination of aortic anulus size during valve replacement [J].
Abraham, TP ;
Kon, ND ;
Nomeir, AM ;
Cordell, AR ;
Kitzman, DW .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1997, 10 (02) :149-154
[2]   Transcatheter Aortic Valve Implantation through the Ascending Aorta: An Alternative Option for No-Access Patients [J].
Bauernschmitt, Robert ;
Schreiber, Christian ;
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Hutter, Andrea ;
Tassani, Peter ;
Lange, Ruediger .
HEART SURGERY FORUM, 2009, 12 (01) :E63-E64
[3]   Results of percutaneous and transapical transcatheter aortic valve implantation performed by a surgical team [J].
Bleiziffer, Sabine ;
Ruge, Hendrik ;
Mazzitelli, Domenico ;
Schreiber, Christian ;
Hutter, Andrea ;
Laborde, Jean-Claude ;
Bauernschmitt, Robert ;
Lange, Ruediger .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (04) :615-621
[4]   DOPPLER ECHOCARDIOGRAPHIC ASSESSMENT OF THE ST-JUDE MEDICAL PROSTHETIC VALVE IN THE AORTIC POSITION USING THE CONTINUITY EQUATION [J].
CHAFIZADEH, ER ;
ZOGHBI, WA .
CIRCULATION, 1991, 83 (01) :213-223
[5]   Echocardiography for transcatheter aortic valve implantation [J].
Chin, Derek .
EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2009, 10 (01) :I21-I29
[6]   Severe Valvular Regurgitation and Late Prosthesis Embolization After Percutaneous Aortic Valve Implantation [J].
Clavel, Marie-Annick ;
Dumont, Eric ;
Pibarot, Philippe ;
Doyle, Daniel ;
De Larochelliere, Robert ;
Villeneuve, Jacques ;
Bergeron, Sebastien ;
Couture, Christian ;
Rodes-Cabau, Josep .
ANNALS OF THORACIC SURGERY, 2009, 87 (02) :618-621
[7]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[8]   Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis - First human case description [J].
Cribier, A ;
Eltchaninoff, H ;
Bash, A ;
Borenstein, N ;
Tron, C ;
Bauer, F ;
Derumeaux, G ;
Anselme, F ;
Laborde, F ;
Leon, MB .
CIRCULATION, 2002, 106 (24) :3006-3008
[9]   Small aortic annulus: The hydrodynamic performances of 5 commercially available tissue valves [J].
Eichinger, Walter B. ;
Hettich, Ina M. ;
Lange, Ruediger .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06) :1499-1500
[10]   Percutaneous aortic valve replacement for severe aortic stenosis in high-rick patients using the second- and current third-generation self-expanding CoreValve prosthesis - Device success and 30-day clinical outcome [J].
Grube, Eberhard ;
Schuler, Gerhard ;
Buellesfeld, Lutz ;
Gerckens, Ulrich ;
Linke, Axel ;
Wenaweser, Peter ;
Sauren, Barthel ;
Mohr, Friedrich-Wilhelm ;
Walther, Thomas ;
Zickmann, Bernfried ;
Iversen, Stein ;
Felderhoff, Thomas ;
Cartier, Raymond ;
Bonan, Raoul .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (01) :69-76