Qualitative analysis of trace constituents by ion mobility increment spectrometer

被引:41
作者
Buryakov, IA [1 ]
机构
[1] Russian Acad Sci, Siberian Branch, Design & Technol Inst Instrument Engn Geophys & E, Novosibirsk 630090, Russia
关键词
explosives; ion mobility spectrometry; atmospheric pressure ionization;
D O I
10.1016/S0039-9140(03)00305-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility increment spectrometry (IMIS) is a high sensitive selective ionization technology for detection and identification of ultra-trace constituents, including toxic compounds, CW-agents, drugs and explosives in ambient air or liquid sample. Like an ion mobility spectrometry (IMS), this technology rests on sampling air containing a mixture of trace constituents, its ionization, spatial separation of produced ions and separated ions detection. Unlike IMS, ions of different types in IMIS are separated by ion mobility increment, alpha. Value alpha, is a function of the parameters: electric field strength and form, atmospheric pressure. To exclude the influence of these parameters on an alpha, the method of explosives identification by a standard compound was suggested. As a standard compound iodine was used. The relationship among the mobility coefficient increments equal to the relationship among the compensation voltage) alpha(i)/ alpha(iodine) = U-i/U-iodine is determined, where i are ions of 1,3-dinitrobenzene, 1,3,5-trinitrobenzene, p-mononitrotoluene, 2.4-dinitrotoluene and 2,4,6-trinitrotoluene This relationship is practically independent of the above mentioned parameters in the range 25 < E/N < 90 Td. The limits of the relative error of this relationship are determined both from spectra of individual compounds and nitrocompound-iodine mixtures. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:369 / 375
页数:7
相关论文
共 22 条
[1]  
Asbury GR, 2000, TALANTA, V50, P1291
[2]   A NEW METHOD OF SEPARATION OF MULTI-ATOMIC IONS BY MOBILITY AT ATMOSPHERIC-PRESSURE USING A HIGH-FREQUENCY AMPLITUDE-ASYMMETRIC STRONG ELECTRIC-FIELD [J].
BURYAKOV, IA ;
KRYLOV, EV ;
NAZAROV, EG ;
RASULEV, UK .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1993, 128 (03) :143-148
[3]   Registration of lewisite vapors in air using an ion mobility spectrometer [J].
Buryakov, IA ;
Kolomietz, YN ;
Bolotov, AV ;
Vasin, AI ;
Vlasov, YN .
JOURNAL OF ANALYTICAL CHEMISTRY, 2002, 57 (07) :606-610
[4]   Detection of explosive vapors in the air using an ion drift nonlinearity spectrometer [J].
Buryakov, IA ;
Kolomiets, YN ;
Luppu, BV .
JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 56 (04) :336-340
[5]  
CARNAHAN B, 1996, P 4 INT WORKSH ION M
[6]  
CARNAHAN B, 1996, P 41 ANN ISA AN DIV, P85
[7]  
CARNAHAN BL, 1995, Patent No. 5420424
[8]   Resolving interferences in negative mode ion mobility spectrometry using selective reactant ion chemistry [J].
Daum, KA ;
Atkinson, DA ;
Ewing, RG ;
Knighton, WB ;
Grimsrud, EP .
TALANTA, 2001, 54 (02) :299-306
[9]  
DAUM KA, 2001, INT J IMS, V4, P179
[10]  
Eiceman GA, 2000, FIELD ANAL CHEM TECH, V4, P297, DOI 10.1002/1520-6521(2000)4:6<297::AID-FACT50>3.0.CO