Influence of bone tissue density and elasticity on ultrasound propagation:: An in vitro study

被引:61
作者
De Terlizzi, F [1 ]
Battista, S
Cavani, F
Canè, V
Cadossi, R
机构
[1] IGEA, Lab Clin Biophys, Carpi Mo, Italy
[2] Univ Modena, Dept Morphol & Medicolegal Sci, I-41100 Modena, Italy
关键词
ultrasound; bone; elasticity; density; signal processing;
D O I
10.1359/jbmr.2000.15.12.2458
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ultrasound (US) waves are mechanical vibrations that are applied to a material-bone tissue-in order to study its properties, that is, density, elasticity, and structure. In this study we evaluated in which way density and elasticity of the spongy bone influenced the transmission of 1.25 MHz US pulses. Twelve cylindrical specimens (diameter, 8 mm; height, 5 mm) excised from phalanxes of pig were decalcified with 0.5 M EDTA for different times (0, 2, and 5 days). During these periods, the samples underwent the following investigations: US transmission, density, and elasticity measurements. To assess the homogeneity of decalcification, the cross-sections of some samples were microradiographed. A detailed analysis of the US signal received was performed using velocity, Fourier analysis, and some parameters typical of signal processing technique. A good correlation was found between US velocity and density (r(2) = 0.70); a lower correlation was found between velocity and elasticity (r(2) = 0.59). If density and elasticity are considered simultaneously, the correlation with the US velocity improves significantly (r(2) = 0.84). Fourier analysis enabled us to observe a shift of the main frequency toward lower values as the decalcification process advanced. We also observed that in the regressions weighted for density, US velocity correlated poorly with elasticity (r(2) = 0.16), whereas signal processing parameters maintain a good correlation with elasticity (ultrasound peak amplitude [UPA], r(2) = 0.48; slope, r(2) = 0.62). In this study, it has been observed that when using a signal processing technique to analyze US pulses, it is possible to identify some parameters that are related in different ways to density and to elastic properties of bone. Our results show the potentiality of US technique to separate information on bone density and elasticity that X-ray-based densitometric methods do not provide.
引用
收藏
页码:2458 / 2466
页数:9
相关论文
共 43 条
[1]   A SURVEY OF OSTEOPOROSIS USING THE CALCANEUM AS AN INDEX [J].
AGGARWAL, ND ;
SINGH, GD ;
AGGARWAL, R ;
KAUR, RP ;
THAPAR, SP .
INTERNATIONAL ORTHOPAEDICS, 1986, 10 (02) :147-153
[2]   Correlation of ultrasound bone velocity with dual-energy x-ray bone absorptiometry in rat bone specimens [J].
Amo, C ;
Revilla, M ;
Hernandez, ER ;
GonzalezRiola, J ;
Villa, LF ;
Seco, C ;
Rico, H .
INVESTIGATIVE RADIOLOGY, 1996, 31 (02) :114-117
[3]  
ARMITAGE P, 1994, STAT METHODS MED RES, P317
[4]   ELASTIC PROPERTIES OF CANCELLOUS BONE - MEASUREMENT BY AN ULTRASONIC TECHNIQUE [J].
ASHMAN, RB ;
CORIN, JD ;
TURNER, CH .
JOURNAL OF BIOMECHANICS, 1987, 20 (10) :979-986
[5]   ELASTIC-MODULUS OF TRABECULAR BONE MATERIAL [J].
ASHMAN, RB ;
RHO, JY .
JOURNAL OF BIOMECHANICS, 1988, 21 (03) :177-181
[6]   A CONTINUOUS WAVE TECHNIQUE FOR THE MEASUREMENT OF THE ELASTIC PROPERTIES OF CORTICAL BONE [J].
ASHMAN, RB ;
COWIN, SC ;
VANBUSKIRK, WC ;
RICE, JC .
JOURNAL OF BIOMECHANICS, 1984, 17 (05) :349-361
[7]  
BATTISTA S, 1998, OSTEOPOROS INT S3, V8, P128
[8]   Broadband ultrasound attenuation predicts fractures strongly and independently of densitometry in older women - A prospective study [J].
Bauer, DC ;
Gluer, CC ;
Cauley, JA ;
Vogt, TM ;
Ensrud, KE ;
Genant, HK ;
Black, DM .
ARCHIVES OF INTERNAL MEDICINE, 1997, 157 (06) :629-634
[9]   Ultrasound velocity through the phalanges in normal and osteoporotic patients [J].
Blanckaert, F ;
Cortet, B ;
Coquerelle, P ;
Flipo, RM ;
Duquesnoy, B ;
Delcambre, B .
CALCIFIED TISSUE INTERNATIONAL, 1999, 64 (01) :28-33
[10]  
BUCKWALTER JA, 1995, AM J BONE JOINT SURG, V8, P1256