Contrast-enhanced peripheral MR angiography from the abdominal aorta to the pedal arteries - Combined dynamic two-dimensional and bolus-chase three-dimensional acquisitions

被引:89
作者
Wang, Y
Winchester, PA
Khilnani, NM
Lee, HM
Watts, R
Trost, DW
Bush, HL
Kent, KC
Prince, MR
机构
[1] Cornell Univ, Weill Med Coll, Dept Radiol, New York, NY 10021 USA
[2] Cornell Univ, Weill Med Coll, Dept Vasc Surg, New York, NY 10021 USA
关键词
peripheral vascular disease; MR angiography; MR digital subtraction angiography; bolus chase;
D O I
10.1097/00004424-200103000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES, TO Obtain reliable contrast-enhanced peripheral MR angiography for imaging peripheral vascular disease from the abdominal aorta to the pedal arteries. METHODS, A protocol consisting of contrast-enhanced, dynamic two-dimensional (2D) acquisition at the feet and calf and bolus-chase three-dimensional (3D) acquisition from the abdominal aorta to the calf was developed and applied in patients with peripheral vascular disease, The performance of this integrated protocol was assessed in 89 consecutive patients, RESULTS. The bolus-chase 3D acquisition was of diagnostic quality in 100% of the acquisitions in the abdomen, 96% in the thigh, and 43% in the calf, The poor quality of the calf acquisitions was due to insufficient spatial resolution, poor arterial signal, and venous contamination. Diagnostic-quality images were obtained in 100% of the dynamic 2D acquisitions of the calf and 98% of the feet. CONCLUSIONS, The combined dynamic 2D and bolus-chase 3D contrast-enhanced MR angiography technique provides diagnostic images of the entire lower extremity.
引用
收藏
页码:170 / 177
页数:8
相关论文
共 34 条
[1]   BYPASS GRAFTS TO THE ANKLE AND FOOT - A PERSONAL PERSPECTIVE [J].
ANDROS, G .
SURGICAL CLINICS OF NORTH AMERICA, 1995, 75 (04) :715-729
[2]  
[Anonymous], 2007, Biostatistical analysis
[3]  
DARDIK H, 1981, SURG GYNECOL OBSTET, V152, P645
[4]  
DEBAKEY ME, 1985, ANN SURG, V201, P115
[5]   Gadolinium-enhanced three-dimensional MR angiography of the entire aorta and iliac arteries with dynamic manual table translation [J].
Earls, JP ;
DeSena, S ;
Bluemke, DA .
RADIOLOGY, 1998, 209 (03) :844-849
[6]   Steady-state and dynamic MR angiography with MS-325: Initial experience in humans [J].
Grist, TM ;
Korosec, FR ;
Peters, DC ;
Witte, S ;
Walovitch, RC ;
Dolan, RP ;
Bridson, WE ;
Yucel, EK ;
Mistretta, CA .
RADIOLOGY, 1998, 207 (02) :539-544
[7]  
HAIMOVICI H, 1967, ARCH SURG-CHICAGO, V95, P918
[8]  
HO K, 1999, THESIS U MAASTRICHT
[9]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692
[10]  
Ho VB, 1999, JMRI-J MAGN RESON IM, V10, P376, DOI 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO