The measurement of thermal neutron flux depression for determining the concentration of boron in blood

被引:5
作者
Brooke, SL [1 ]
Green, S
Charles, MW
Beddoe, AH
机构
[1] Queen Elizabeth Hosp, Dept Med Phys, Birmingham B15 2TH, W Midlands, England
[2] Univ Birmingham, Sch Phys & Astron, Birmingham B15 2TT, W Midlands, England
关键词
D O I
10.1088/0031-9155/46/3/307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Boron neutron capture therapy (BNCT) is a form of targeted radiotherapy that relies on the uptake of the capture element boron by the volume to be treated. The treatment procedure requires the measurement of boron in the patient's blood, The investigation of a simple and inexpensive method for determining the concentration of the capture element B-10 in blood is described here. This method, neutron flux depression measurement, involves the determination of the flux depression of thermal neutrons as they pass through a boron-containing sample, It is shown via Monte Carlo calculations and experimental verification that, for a maximum count rate of 1 x 10(4) counts/s measured by the detector, a 10 ppm B-10 sample of volume 20 ml can be measured with a statistical precision of 10% in 32 +/- 2 min, For a source activity of less than 1.11 x 10(11) Bq and a maximum count, rate of less than 1 x 10(4) counts/s, a 10 ppm B-10 sample of volume 20 mi can be measured with a statistical precision of 10% in 58 +/- 3 min. It has also been shown that this technique can be applied to the measurement of the concentration of any element with a high thermal neutron cross section such as Gd-157.
引用
收藏
页码:707 / 715
页数:9
相关论文
共 15 条
[1]   DETERMINATION OF BORON IN TISSUES AND CELLS USING DIRECT-CURRENT PLASMA ATOMIC EMISSION-SPECTROSCOPY [J].
BARTH, RF ;
ADAMS, DM ;
SOLOWAY, AH ;
MECHETNER, EB ;
ALAM, F ;
ANISUZZAMAN, AKM .
ANALYTICAL CHEMISTRY, 1991, 63 (09) :890-893
[2]  
BARTH RF, 1992, CANCER-AM CANCER SOC, V70, P2995
[3]  
BAUER WF, 1993, ADVANCES IN NEUTRON CAPTURE THERAPY, P403
[4]  
BOMBARDIER F, 1996, THESIS U BIRMINGHAM
[5]   Biodistribution of boronophenylalanine in patients with glioblastoma multiforme: Boron concentration correlates with tumor cellularity [J].
Coderre, JA ;
Chanana, AD ;
Joel, DD ;
Elowitz, EH ;
Micca, PL ;
Nawrocky, MM ;
Chadha, M ;
Gebbers, JO ;
Shady, M ;
Peress, NS ;
Slatkin, DN .
RADIATION RESEARCH, 1998, 149 (02) :163-170
[6]   The radiation biology of boron neutron capture therapy [J].
Coderre, JA ;
Morris, GM .
RADIATION RESEARCH, 1999, 151 (01) :1-18
[7]   MICROANALYTICAL TECHNIQUES FOR BORON ANALYSIS USING THE B-10(N,ALPHA)LI-7 REACTION [J].
FAIRCHILD, RG ;
GABEL, D ;
LASTER, BH ;
GREENBERG, D ;
KISZENICK, W ;
MICCA, PL .
MEDICAL PHYSICS, 1986, 13 (01) :50-56
[8]  
International Commission on Radiological Protection, 1975, REPORT TASK GROUP RE
[9]  
MEEHAN A, 1996, THESIS U BIRMINGHMAM
[10]   Measurement of total boron and 10B concentration and the detection and measurement of elevated 10B levels in biological samples by inductively coupled plasma mass spectrometry using the determination of 10B:11B ratios [J].
Moreton, JA ;
Delves, HT .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (10) :1545-1556