Comparison of fluorescent BACTEC 9000 MB system, Septi-Chek AFB system, and Lowenstein-Jensen medium for detection of mycobacteria

被引:32
作者
vanGriethuysen, AJ [1 ]
Jansz, AR [1 ]
Buiting, AGM [1 ]
机构
[1] DEPT CLIN MICROBIOL,LAB PATHOL & MED MICROBIOL,NL-5500 AA VELDHOVEN,NETHERLANDS
关键词
D O I
10.1128/JCM.34.10.2391-2394.1996
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
The newly developed fluorescent BACTEC 9000 MB system for automated culture of mycobacteria was compared with the Septi-Chek AFB system and Lowenstein-Jensen medium (LJ). A total of 2,005 clinical specimens were included in the study. Mycobacteria mere isolated from 202 (10.1%) specimens, including 155 Mycobacterium tuberculosis complex isolates and 47 Mycobacteria other than M. tuberculosis isolates. Of 131 isolates detected by the BACTEC system, the Septi-Chek AFB system, or both, 120 (91.6% were detected by the BACTEC system and 105 (80.2%) were detected by the Septi-Chek AFB system (P < 0.02). The recovery rate in the BACTEC system compared with that in the Septi-Chek AFB system was significantly higher for M. tuberculosis complex isolates (P < 0.005) and for isolates from acid-fast smear-negative specimens (P < 0.01). Of 148 isolates detected by the BACTEC system, LJ, or both, 142 (95.9%) were detected by the BACTEC system and 118 (79.9%) were detected by LJ (P < 0.001). The recovery rate in the BACTEC system compared with that on LJ was significantly higher for M. tuberculosis complex isolates (P < 0.001). The BACTEC system detected more mycobacteria from both smear-positive and smear-negative specimens than LJ. The mean times to detection of mycobacteria were 17.6 days for the BACTEC system, 26.0 days for the Septi-Chek AFB system, and 29.4 days for LJ. The BACTEC fluorescent 9000 MB system is a rapid, sensitive, and efficient method for the isolation of mycobacteria.
引用
收藏
页码:2391 / 2394
页数:4
相关论文
共 26 条
[1]   COMPARISON OF MB-CHECK, BACTEC, AND EGG-BASED MEDIA FOR RECOVERY OF MYCOBACTERIA [J].
ABE, C ;
HOSOJIMA, S ;
FUKASAWA, Y ;
KAZUMI, Y ;
TAKAHASHI, M ;
HIRANO, K ;
MORI, T .
JOURNAL OF CLINICAL MICROBIOLOGY, 1992, 30 (04) :878-881
[2]   COMPARISON OF IMPROVED BACTEC AND LOWENSTEIN-JENSEN MEDIA FOR CULTURE OF MYCOBACTERIA FROM CLINICAL SPECIMENS [J].
ANARGYROS, P ;
ASTILL, DSJ ;
LIM, ISL .
JOURNAL OF CLINICAL MICROBIOLOGY, 1990, 28 (06) :1288-1291
[3]  
BOYYLE JF, 1995, 95 GEN M AM SOC MICR, P142
[4]  
CHAPIN K, MANUAL CLIN MICROBIO, P33
[5]   EVALUATION OF THE ROCHE SEPTI-CHEK AFB SYSTEM FOR RECOVERY OF MYCOBACTERIA [J].
DAMATO, RF ;
ISENBERG, HD ;
HOCHSTEIN, L ;
MASTELLONE, AJ ;
ALPERSTEIN, P .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (12) :2906-2908
[6]  
ELSTON RC, 1987, ESSENTIALS BIOSTATIS, P155
[7]   EVALUATION OF A NEW BIPHASIC CULTURE SYSTEM FOR THE RECOVERY OF MYCOBACTERIA [J].
GIGER, T ;
BURKARDT, HJ .
EUROPEAN JOURNAL OF CLINICAL MICROBIOLOGY & INFECTIOUS DISEASES, 1990, 9 (06) :428-431
[8]  
HAAS DW, 1995, MANDELL DOUGLAS BENN, P2213
[9]  
Havlir DVEJ, 1995, MANDELL DOUGLAS BENN, P2250
[10]   MYCOBACTERIUM-MALMOENSE - AN EASILY MISSED PATHOGEN [J].
HOFFNER, SE ;
HENRIQUES, B ;
PETRINI, B ;
KALLENIUS, G .
JOURNAL OF CLINICAL MICROBIOLOGY, 1991, 29 (11) :2673-2674