Enzyme-linked Immunosorbent assay of Escherichia coli O157:H7 in surface enhanced Poly(Methyl methacrylate) microchannels

被引:27
作者
Bai, Yunling [1 ]
Huang, Wei-Cho [1 ]
Yang, Shang-Tian [1 ]
机构
[1] Ohio State Univ, Dept Chem & Biomol Engn, Columbus, OH 43210 USA
关键词
immunoassay; ELISA; microchannel; Escherichia coli; poly(ethyleneimine); biochip;
D O I
10.1002/bit.21429
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A novel surface treatment method was developed to enhance polymer-based microchannel enzyme-linked immunosorbent assay (ELISA) for Escherichia coli O157:H7 detection. By applying an amine-bearing polymer, poly(ethyleneimine) (PEI), onto poly(methyl methacrylate) (PMMA) surface at pH higher than 11, PEI molecules were covalently attached and their amine groups were introduced to PMMA surface. Zeta potential analysis and X-ray photoelectron spectroscopy (XPS) demonstrated that the alkali condition is preferable for PEI attachment onto the PMMA surface. The amine groups on the PMMA surface were then functionalized with glutaraldehyde, whose aldehyde groups served as the active sites for binding the antibody by forming covalent bonds with the amine groups of the protein molecules. This surface modification greatly improved antibody binding efficiency and the microchannel ELISA for E. coli O157:1-17 detection. Compared with untreated PMMA microchannels, similar to 45 times higher signal and 3 times higher signal/noise ratio were achieved with the PEI surface treatment, which also shortened the time required for cells to bind to the microchannel surface to similar to 2 min, much less than that usually required for the same ELISA carried out in 96-well plates. The detection in the microchannel ELISA only required 5-8 cells per sample, which is also better than 15-30 cells required in multi-well plates. With the high sensitivity, short assay time, and small reagent consumption, the microchannel ELISA can be economically used for fast detection of E. coli O157:H7.
引用
收藏
页码:328 / 339
页数:12
相关论文
共 22 条
[1]   Functional peptide microarrays for specific and sensitive antibody diagnostics [J].
Andresen, H ;
Grötzinger, C ;
Zarse, K ;
Kreuzer, OJ ;
Ehrentreich-Förster, E ;
Bier, FF .
PROTEOMICS, 2006, 6 (05) :1376-1384
[2]   Surface modification for enhancing antibody binding on polymer-based microfluidic device for enzyme-linked immunosorbent assay [J].
Bai, Yunling ;
Koh, Chee Guan ;
Boreman, Megan ;
Juang, Yi-Je ;
Tang, I-Ching ;
Lee, L. James ;
Yang, Shang-Tian .
LANGMUIR, 2006, 22 (22) :9458-9467
[3]  
Bulmus V, 1997, CHEM ENG J, V65, P71, DOI 10.1016/S0923-0467(96)03156-9
[4]   A microchip-based enzyme assay for protein kinase A [J].
Cohen, CB ;
Chin-Dixon, E ;
Jeong, S ;
Nikiforov, TT .
ANALYTICAL BIOCHEMISTRY, 1999, 273 (01) :89-97
[5]   Electrokinetically driven microfluidic chips with surface-modified chambers for heterogeneous immunoassays [J].
Dodge, A ;
Fluri, K ;
Verpoorte, E ;
de Rooij, NF .
ANALYTICAL CHEMISTRY, 2001, 73 (14) :3400-3409
[6]   Development and characterization of an ELISA assay in PDMS microfluidic channels [J].
Eteshola, E ;
Leckband, D .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 72 (02) :129-133
[7]  
Ferreira JL, 2001, J AOAC INT, V84, P1460
[8]   Functionalization of poly(methyl methacrylate) (PMMA) as a substrate for DNA microarrays [J].
Fixe, F ;
Dufva, M ;
Telleman, P ;
Christensen, CBV .
NUCLEIC ACIDS RESEARCH, 2004, 32 (01) :e9
[9]   A novel ELISA format for the rapid and sensitive detection of staphylococcal enterotoxin A [J].
Giletto, A ;
Fyffe, JG .
BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 1998, 62 (11) :2217-2222
[10]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412