Real-time system for respiratory-cardiac gating in positron tomography

被引:99
作者
Klein, GJ
Reutter, BW
Ho, MH
Reed, JH
Huesman, RH
机构
[1] Univ Calif Berkeley, Lawrence Berkeley Lab, Ctr Funct Imaging, Berkeley, CA 94720 USA
[2] CTI Inc, Knoxville, TN 37932 USA
关键词
D O I
10.1109/23.708323
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A Macintosh-based signal processing system has been developed to support simultaneous respiratory and cardiac gating on the ECAT EXACT HR PET scanner. Using the Lab-View real-time software environment, the system reads analog inputs from a pneumatic respiratory bellows and an ECG monitor to compute an appropriate histogram memory location for the PET data. Respiratory state is determined by the bellows signal amplitude; cardiac state is based on the time since the last R-wave. These two states are used in a 2D lookup table to determine a combined respiratory-cardiac state. A 4-bit address encoding the selected histogram is directed from the system to the ECAT scanner, which dynamically switches the destination of tomograph events as respiratory-cardiac state changes. To test the switching efficiency of the combined Macintosh/ECAT system, a rotating emission phantom was built, Acquisitions with 25 msec states while the phantom was rotating at 240 rpm demonstrate the system could effectively stop motion at this rate, with approximately 5 msec switching time between states.
引用
收藏
页码:2139 / 2143
页数:5
相关论文
共 11 条
  • [1] Budinger T. F., 1996, Journal of Nuclear Medicine, V37, p130P
  • [2] THE ELECTRONICS FOR THE DONNER 600-CRYSTAL POSITRON TOMOGRAPH
    CAHOON, JL
    HUESMAN, RH
    DERENZO, SE
    GEYER, AB
    UBER, DC
    TURKO, BT
    BUDINGER, TF
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1986, 33 (01) : 570 - 574
  • [3] QUANTITATION IN POSITRON EMISSION COMPUTED-TOMOGRAPHY .1. EFFECT OF OBJECT SIZE
    HOFFMAN, EJ
    HUANG, SC
    PHELPS, ME
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 299 - 308
  • [4] Huesman R. H., 1997, Journal of Nuclear Medicine, V38, p114P
  • [5] Non-rigid summing of gated PET via optical flow
    Klein, GJ
    Reutter, BW
    Huesman, RH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (04) : 1509 - 1512
  • [6] A 3D optical flow approach to addition of deformable PET volumes
    Klein, GJ
    Huesman, RH
    [J]. IEEE NONRIGID AND ARTICULATED MOTION WORKSHOP, PROCEEDINGS, 1997, : 136 - 143
  • [7] PROSPECTIVELY GATED CARDIAC COMPUTED-TOMOGRAPHY
    MOORE, SC
    JUDY, PF
    GARNIC, JD
    KAMBIC, GX
    BONK, F
    COCHRAN, G
    MARGOSIAN, P
    MCCROSKEY, W
    FOOTE, F
    [J]. MEDICAL PHYSICS, 1983, 10 (06) : 846 - 855
  • [8] EFFICIENT BIPHASIC SPIN-ECHO MAGNETIC-RESONANCE IMAGING
    PARKER, DL
    CAPUTO, GR
    FREDERICK, PR
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1989, 11 (01) : 98 - 113
  • [9] Reutter B. W., 1997, Journal of Nuclear Medicine, V38, p203P
  • [10] Automated 3-D segmentation of respiratory-gated PET transmission images
    Reutter, BW
    Klein, GJ
    Huesman, RH
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1997, 44 (06) : 2473 - 2476