An environmental monitoring system for trace metals using stripping voltammetry

被引:64
作者
Desmond, D [1 ]
Lane, B
Alderman, J
Hill, M
Arrigan, DWM
Glennon, JD
机构
[1] Natl Univ Ireland Univ Coll Cork, Dept Chem, Lab B16, Cork, Ireland
[2] Natl Univ Ireland Univ Coll Cork, Natl Microelect Res Ctr, Inst Adv Microelect, Cork, Ireland
[3] Univ Salford, Div Chem Sci, Sci Res Inst, Salford M5 4WT, Lancs, England
关键词
trace metals; ppb; anodic stripping voltammetry (ASV); reference electrode; disposable sensor;
D O I
10.1016/S0925-4005(98)00078-1
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
There is increasing pressure on industry and regulatory bodies to monitor the discharge of trace metals into the aquatic environment. The determination of trace metals can be.achieved to parts per billion (ppb) levels using anodic stripping voltammetry (ASV) at screen printed electrodes, controlled using an NMRC potentiostat coupled with software control. The disposable testheads consist of inexpensive materials and allow for low-cost production in batch processes. Voltammetric (the measurement of current as a function of potential) methods of analysis are attractive for the determination of copper, cadmium, lead and zinc. A three electrode set-up is used both in the preparation of the mercury film on a carbon electrode and in the subsequent anodic stripping voltammetric detection step. The performances of the reference electrodes, the screen-printed carbon and the FPGA based unit have been investigated in this paper. (C) 1998 Elsevier Science S.A. All rights reserved.
引用
收藏
页码:409 / 414
页数:6
相关论文
共 20 条
  • [1] BOND AM, 1990, Z CHEM, V30, P117
  • [2] An ASIC-based system for stripping voltammetric determination of trace metals
    Desmond, D
    Lane, B
    Alderman, J
    Hall, G
    AlvarezIcaza, M
    Garde, A
    Ryan, J
    Barry, L
    Svehla, G
    Arrigan, DWM
    Schniffner, L
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1996, 34 (1-3) : 466 - 470
  • [3] Evaluation of miniaturised solid state reference electrodes on a silicon based component
    Desmond, D
    Lane, B
    Alderman, J
    Glennon, JD
    Diamond, D
    Arrigan, DWM
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1997, 44 (1-3) : 389 - 396
  • [4] EVALUATION OF A NEW SOLID-STATE REFERENCE ELECTRODE JUNCTION MATERIAL FOR ION-SELECTIVE ELECTRODES
    DIAMOND, D
    MCENROE, E
    MCCARRICK, M
    LEWENSTAM, A
    [J]. ELECTROANALYSIS, 1994, 6 (11-12) : 962 - 971
  • [5] DISPOSABLE REFERENCE ELECTRODE
    DIEKMANN, C
    DUMSCHAT, C
    CAMMANN, K
    KNOLL, M
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 1995, 24 (1-3) : 276 - 278
  • [6] FLORENCE TM, 1972, J ELECTROANAL CHEM, V35, P237, DOI 10.1016/0368-1874(72)80063-7
  • [7] GREEN MJ, 1991, ANAL P, V28, P374
  • [8] ILLINGWORTH JA, 1981, J BIOCH, V195, P229
  • [9] THE PREPARATION IN-SITU OF A SILVER SILVER-CHLORIDE REFERENCE ELECTRODE
    KULYS, J
    MUNK, JA
    BUCHRASMUSSEN, T
    HANSEN, HE
    [J]. ELECTROANALYSIS, 1994, 6 (11-12) : 945 - 952
  • [10] Miniaturized reference electrodes with microporous polymer junctions
    Pedrotti, JJ
    Angnes, L
    Gutz, IGR
    [J]. ELECTROANALYSIS, 1996, 8 (07) : 673 - 675