Influence of instrument size on endoscopic task performance in pediatric intracorporeal knot tying - Smaller instruments are better in infants

被引:17
作者
Lee, Alex C. H.
Haddad, Munther J.
Hanna, George B.
机构
[1] Univ London Imperial Coll Sci Technol & Med, St Marys Hosp, Dept Biosurg & Surg Technol, London W2 1NY, England
[2] Chelsea & Westminster Hosp, Dept Paediat Surg, London SW10 9NH, England
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2007年 / 21卷 / 11期
关键词
electromyography; ergonomics; infants; minimal access surgery; knot quality score;
D O I
10.1007/s00464-007-9311-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The widespread availability of adult minimal access surgical (MAS) equipment together with resource constraints have led pediatric surgeons to adopt the adult setup. This study examined the influence of instrument size on task outcome and physical impact on the surgeon in pediatric endoscopic intracorporeal knot tying. Methods: Sixteen surgeons participated in this study in which they had to tie surgeon's knots inside a neonatal simulator box with an endoscopic field of 40 mm. All surgeons tied 20 knots using paired pediatric needle-holders and 20 knots using paired adult needle-holders in a randomized order. Knot quality score (KQS) and wrap length were used as indices of knot quality and wrap tightness. Electromyographic (EMG) recordings of the upper limb muscle groups were used to indicate muscular recruitment. A questionnaire on discomfort and instrument preference was also completed by the surgeons. Results: A total of 640 knots were analyzed. Median time was shorter for pediatric needle-holders than for adult needle-holders (94 s vs. 103 s; p < 0.001); however KQS (0.271 vs. 0.260; p = 0.509) and the tightness around the tube (86 mm vs. 86 mm; p = 0.255) were not significantly different. The proportion of knots that completely slipped was also similar for both needle-holders (19% vs. 22%; p = 0.322). The normalized EMG values when using adult needle-holders were significantly higher than when using pediatric needle-holders in all upper limb muscle groups with the exception of left forearm extensors (p = 0.460). The surgeons reported less discomfort with the pediatric needle-holders in the right forearm and hand, and 13 surgeons expressed overall preference for the smaller instruments. Conclusion: Endoscopic knot tying was performed faster in the neonatal simulator box using pediatric needle-holders while maintaining knot quality. Upper limb muscular recruitment was reduced resulting in less discomfort for the surgeon.
引用
收藏
页码:2086 / 2090
页数:5
相关论文
共 19 条
[1]
A comparison of surgeons' posture during laparoscopic and open surgical procedures [J].
Berguer, R ;
Rab, GT ;
AbuGhaida, H ;
Alarcon, A ;
Chung, J .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (02) :139-142
[2]
Ergonomic problems associated with laparoscopic surgery [J].
Berguer, R ;
Forkey, DL ;
Smith, WD .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (05) :466-468
[3]
An ergonomic study of the optimum operating table height for laparoscopic surgery [J].
Berquer, R ;
Smith, WD ;
Davis, S .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2002, 16 (03) :416-421
[4]
Normalisation of EMG amplitude: an evaluation and comparison of old and new methods [J].
Burden, A ;
Bartlett, R .
MEDICAL ENGINEERING & PHYSICS, 1999, 21 (04) :247-257
[6]
The use of surface electromyography in biomechanics [J].
De Luca, CJ .
JOURNAL OF APPLIED BIOMECHANICS, 1997, 13 (02) :135-163
[7]
Effect of intracorporeal-extracorporeal instrument length ratio on endoscopic task performance and surgeon movements [J].
Emam, TA ;
Hanna, GB ;
Kimber, C ;
Dunkley, P ;
Cuschieri, A .
ARCHIVES OF SURGERY, 2000, 135 (01) :62-65
[8]
Influence of the optical axis-to-target view angle on endoscopic task performance [J].
Hanna, GB ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1999, 13 (04) :371-375
[9]
Task performance in endoscopic surgery is influenced by location of the image display [J].
Hanna, GB ;
Shimi, SM ;
Cuschieri, A .
ANNALS OF SURGERY, 1998, 227 (04) :481-484
[10]
Optimal port locations for endoscopic intracorporeal knotting [J].
Hanna, GB ;
Shimi, S ;
Cuschieri, A .
SURGICAL ENDOSCOPY-ULTRASOUND AND INTERVENTIONAL TECHNIQUES, 1997, 11 (04) :397-401