ECG-based detection of body position changes in ischemia monitoring

被引:34
作者
García, J
Åström, M
Mendive, J
Laguna, P
Sörnmo, L
机构
[1] Univ Zaragoza, Polytech Ctr, Aragon Inst Engn Res 13A, Commun Technol Grp, Zaragoza 50018, Spain
[2] Lund Univ, Dept Electrosci, Commun Technol Grp GTC Aragon, SE-22100 Lund, Sweden
关键词
alarms; body position changes; detection; ECG; ischemia;
D O I
10.1109/TBME.2003.812208
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this gaper is to analyze and detect changes in body position (BPC) during electrocardiogram (ECG) recording. These changes are often manifested as shifts in the, electrical axis and may be misclassified as ischemic changes during. ambulatory monitoring. We investigate two ECG signal processing methods for detecting BPCs. Different schemes for feature extraction are used (spatial and scalar), while preprocessing, trend postprocessing and detection are identical. The spatial approach is based on VCG loop rotation angles and the scalar approach is based on the Karhunen-Loeve transform (KLT) coefficients. The methods are evaluated on two different databases: a database with annotated BPCs and the STAFF III database with recordings from rest and during angioplasty-induced ischemia but not including BPCs. The angle-based detector results in performance values of detection probability P-D = 95%, false alarm probability P-F = 3% in the BPC database and false alarm rate in the STAFF III database in control ECCs during rest R-F(c) = 2 h(-1) (episodes per hour) and in ischemia recordings during angioplasty R-F(a) = 7 h(-1), whereas the KLT-based detector produces values of P-D = 89%, P-F = 3%, R-F(c) = 4 h(-1), and RF(a) = 11 h-1, respectively. Including information on noise level in the detection process to reduce the number of false alarms, performance values of P-D similar or equal to 90%, P-F similar or equal to 1%, R-F(c) similar or equal to 1 h(-1) and R-F(a) similar or equal to 2 h(-1) are obtained with both methods. It is concluded that reliable detection of BPCs may be achieved using the ECG signal and should work in parallel to ischemia detectors.
引用
收藏
页码:677 / 685
页数:9
相关论文
共 22 条
[1]   Body position effects on the ECG - Implication for ischemia monitoring [J].
Adams, MG ;
Drew, BJ .
JOURNAL OF ELECTROCARDIOLOGY, 1997, 30 (04) :285-291
[2]  
[Anonymous], 1986, ROBUST STAT
[3]  
[Anonymous], 1998, FUNDEMENTALS STAT SI
[4]  
[Anonymous], 1992, DISCRETE RANDOM SIGN
[5]  
[Anonymous], 1968, SER DETECTION ESTIMA
[6]   Detection of body position changes using the surface electrocardiogram [J].
Åström, M ;
García, J ;
Laguna, P ;
Pahlm, O ;
Sörnmo, L .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (02) :164-171
[7]   VECTORCARDIOGRAM SYNTHESIZED FROM A 12-LEAD ECG - SUPERIORITY OF THE INVERSE DOWER MATRIX [J].
EDENBRANDT, L ;
PAHLM, O .
JOURNAL OF ELECTROCARDIOLOGY, 1988, 21 (04) :361-367
[8]   Automatic detection of ST-T complex changes on the ECG using filtered RMS difference series:: Application to ambulatory ischemia monitoring [J].
García, J ;
Sörnmo, L ;
Olmos, S ;
Laguna, P .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (09) :1195-1201
[9]   Comparative study of local and Karhunen-Loeve-based ST-T indexes in recordings from human subjects with induced myocardial ischemia [J].
García, J ;
Lander, P ;
Sörnmo, L ;
Olmos, S ;
Wagner, G ;
Laguna, P .
COMPUTERS AND BIOMEDICAL RESEARCH, 1998, 31 (04) :271-292
[10]   Temporal evolution of traditional versus transformed EGG-based indexes in patients with induced myocardial ischemia [J].
García, J ;
Wagner, G ;
Sörnmo, L ;
Olmos, S ;
Lander, P ;
Laguna, P .
JOURNAL OF ELECTROCARDIOLOGY, 2000, 33 (01) :37-47