Lead- and device-related complications in the Antiarrhythmics versus implantable defibrillators trial

被引:103
作者
Kron, J
Herre, J
Renfroe, EG
Rizo-Patron, C
Raitt, M
Halperin, B
Gold, M
Goldner, B
Wathen, M
Wilkoff, B
Olarte, A
Yao, Q
机构
[1] Oregon Hlth Sci Univ, Portland, OR USA
[2] Sentara Norfolk Gen Hosp, Norfolk, VA USA
[3] Univ Washington, Seattle, WA 98195 USA
[4] Cardiol Assoc, Lubbock, TX USA
[5] Univ Maryland, College Pk, MD 20742 USA
[6] N Shore Univ Hosp, New York, NY USA
[7] Vanderbilt Univ, Med Ctr, Nashville, TN USA
[8] Cleveland Clin Fdn, Cleveland, OH 44195 USA
关键词
D O I
10.1067/mhj.2001.111261
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Implantation of transvenous implantable cardioverter defibrillators (ICDs) by use of a nonthoracotomy approach has become routine therapy for survivors of life-threatening tachyarrhythmias. The purpose of this study was to identify and prospectively characterize the frequency of lead- and ICD-related complications from the Antiarrhythmics versus Implantable Defibrillators (AVID) Trial. Methods and Results Between June 1, 1993, and April 7, 1997, 539 patients received nonthoracotomy ICDs either as initial treatment assignment (477) or as crossover from medical management (62). A total of 62 first complications occurred. The subclavian route of insertion resulted in more complications than the cephalic vein route, 46 of 339 (14%) versus 6 of 135 (4%), P = .005, as did the abdominal versus pectoral generator site, 31 of 238 (13%) versus 17 of 291 (6%), P < .02. Most dislodgements and system infections tended to occur in the 3 months after implantation, whereas lead fractures continued to occur throughout follow-up. Failure to use perioperative antibiotics was a predictor of system infection (P = .001). Conclusions These data suggest that cephalic vein access and pectoral generator site may result in fewer complications. The continued occurrence of lead fractures and the need for premature system revision supports the practice of close routine ICD system surveillance.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 19 条
  • [1] Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator
    Bardy, GH
    Yee, R
    Jung, W
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (02) : 400 - 410
  • [2] BROCKS R, 1994, AM J CARDIOL, V74, P1011
  • [3] CLINICAL-EXPERIENCE WITH THE EXTRATHORACIC INTRODUCER INSERTION TECHNIQUE
    BYRD, CL
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (09): : 1781 - 1784
  • [4] EPSTEIN AE, 1995, AM J CARDIOL, V75, P470
  • [5] ELECTROPHYSIOLOGICAL LABORATORY, ELECTROPHYSIOLOGIST-IMPLANTED, NONTHORACOTOMY-IMPLANTABLE CARDIOVERTER/DEFIBRILLATORS
    FITZPATRICK, AP
    LESH, MD
    EPSTEIN, LM
    LEE, RJ
    SIU, A
    MERRICK, S
    GRIFFIN, JC
    SCHEINMAN, MM
    [J]. CIRCULATION, 1994, 89 (06) : 2503 - 2508
  • [6] Complications associated with pectoral cardioverter-defibrillator implantation: Comparison of subcutaneous and submuscular approaches
    Gold, MR
    Peters, RW
    Johnson, JW
    Shorofsky, SR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (05) : 1278 - 1282
  • [7] ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation)
    Gregoratos, G
    Cheitlin, MD
    Conill, A
    Epstein, AE
    Fellows, C
    Ferguson, TB
    Freedman, RA
    Hlatky, MA
    Naccarelli, GV
    Saksena, S
    Schlant, RC
    Silka, MJ
    [J]. CIRCULATION, 1998, 97 (13) : 1325 - 1335
  • [8] Complications of third-generation implantable cardioverter defibrillator therapy
    Grimm, W
    Menz, V
    Hoffmann, J
    Timmann, U
    Funck, R
    Moosdorf, R
    Maisch, B
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1999, 22 (01): : 206 - 211
  • [9] Long-term survival and complications in patients with malignant ventricular tachyarrhythmias: Treatment with a nonthoracotomy implantable cardioverter defibrillator with or without a subcutaneous patch
    Jafar, MZ
    Schloss, EJ
    Mehdirad, AA
    Keim, S
    Rist, K
    Siddiqui, S
    Tchou, PJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (05): : 1305 - 1311
  • [10] Implantable transvenous cardioverter defibrillator leads: The dark side
    Lawton, JS
    Wood, MA
    Gilligan, DM
    Stambler, BS
    Damiano, RJ
    Ellenbogen, KA
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (09): : 1273 - 1278