Intracoronary radiation for prevention of restenosis - Dose perturbations caused by stents

被引:47
作者
Amols, HI
Trichter, F
Weinberger, J
机构
[1] Columbia Univ, Dept Radiat Oncol, New York, NY 10032 USA
[2] Columbia Univ, Dept Med, New York, NY 10032 USA
[3] Columbia Univ, Dept Pharmacol, New York, NY 10032 USA
关键词
angioplasty; restenosis; brachytherapy; stents; beta rays;
D O I
10.1161/01.CIR.98.19.2024
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Intravascular irradiation with beta-emitters has been proposed for inhibition of restenosis in coronary arteries after balloon angioplasty or stent implantation. Previous studies have shown the effectiveness of gamma-radiation to prevent recurrent restenosis, even in the presence of an implanted scent. The limited range of beta-particles compared with gamma-radiation, however, opens the question of whether absorption and scattering of beta-particles by stent struts will cause significant perturbations in the uniformity and magnitude of the radiation dose, which may in turn compromise treatment. Methods and Results-Nine different scents were deployed with a balloon filled with a beta-emitting radioactive liquid. Dose distributions were measured with Gafchromic film. Stents varied significantly in their absorption of beta-particles. Some stents, constructed of fine meshed wires, produced minimal dose perturbations. Others, with thicker, high-atomic-number struts, induced cold spots in the close distribution adjacent to the wires of less than or equal to 35%. Average dose reduction varied from 4% to 14% in the presence of various stents. Conclusions-Radiation strategy may have to be tailored to stent design. Stents that minimally perturb the dose distribution may be deployed before irradiation. Those that significantly alter the radiation dose might be better deployed after irradiation. Dose prescriptions may require modification if such perturbations prove clinically significant. Observed dose perturbations, however, decreased rapidly with increasing distance from the stent, which may mitigate the clinical impact of these findings. This, as well as the effects of stents on gamma-dose distributions, requires further investigation.
引用
收藏
页码:2024 / 2029
页数:6
相关论文
共 16 条
  • [1] Dosimetry of a radioactive coronary balloon dilitation catheter for treatment of neointimal hyperplasia
    Amols, HI
    Reinstein, LE
    Weinberger, J
    [J]. MEDICAL PHYSICS, 1996, 23 (10) : 1783 - 1788
  • [2] Dosimetric considerations for catheter-based beta and gamma emitters in the therapy of neointimal hyperplasia in human coronary arteries
    Amols, HI
    Zaider, M
    Weinberger, J
    Ennis, R
    Schiff, PB
    Reinstein, LE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (04): : 913 - 921
  • [3] AMOLS HI, 1996, VASCULAR BRACHYTHERA, P104
  • [4] BOTTCHER HD, 1994, INT J RADIAT ONCOL, V29, P183
  • [5] HIGH-SENSITIVITY GAFCHROMIC FILM DOSIMETRY FOR I-125 SEED
    CHIUTSAO, ST
    DELAZERDA, A
    LIN, J
    KIM, JH
    [J]. MEDICAL PHYSICS, 1994, 21 (05) : 651 - 657
  • [6] PROCESSING OF REACTOR-PRODUCED W-188 FOR FABRICATION OF CLINICAL-SCALE ALUMINA-BASED W-188/RE-188 GENERATORS
    KNAPP, FF
    CALLAHAN, AP
    BEETS, AL
    MIRZADEH, S
    HSIEH, BT
    [J]. APPLIED RADIATION AND ISOTOPES, 1994, 45 (12) : 1123 - 1128
  • [7] High dose rate intracoronary radiation for inhibition of neointimal formation in the stented and balloon-injured porcine models of restenosis: Angiographic, morphometric, and histopathologic analyses
    Mazur, W
    Ali, MN
    Khan, MM
    Dabaghi, SF
    DeFelice, CA
    Paradis, P
    Butler, EB
    Wright, AE
    Fajardo, LF
    French, BA
    Raizner, AE
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (04): : 777 - 788
  • [8] SENSITOMETRY OF THE RESPONSE OF A NEW RADIOCHROMIC FILM DOSIMETER TO GAMMA-RADIATION AND ELECTRON-BEAMS
    MCLAUGHLIN, WL
    YUNDONG, C
    SOARES, CG
    MILLER, A
    VANDYK, G
    LEWIS, DF
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 302 (01) : 165 - 176
  • [9] CLINICAL-TRIALS OF RESTENOSIS AFTER CORONARY ANGIOPLASTY
    POPMA, JJ
    CALIFF, RM
    TOPOL, EJ
    [J]. CIRCULATION, 1991, 84 (03) : 1426 - 1436
  • [10] A COMPARISON OF BALLOON-EXPANDABLE-STENT IMPLANTATION WITH BALLOON ANGIOPLASTY IN PATIENTS WITH CORONARY-ARTERY DISEASE
    SERRUYS, PW
    DEJAEGERE, P
    KIEMENEIJ, F
    MACAYA, C
    RUTSCH, W
    HEYNDRICKX, G
    EMANUELSSON, H
    MARCO, J
    LEGRAND, V
    MATERNE, P
    BELARDI, J
    SIGWART, U
    COLOMBO, A
    GOY, JJ
    VANDENHEUVEL, P
    DELCAN, J
    MOREL, MA
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (08) : 489 - 495