Differences among techniques for high-abundant protein depletion

被引:206
作者
Zolotarjova, N [1 ]
Martosella, J [1 ]
Nicol, G [1 ]
Bailey, J [1 ]
Boyes, BE [1 ]
Barrett, WC [1 ]
机构
[1] Agilent Technol, Wilmington, DE 19808 USA
关键词
albumin; immunodepletion; multiple affinity; protein depletion; serum;
D O I
10.1002/pmic.200402021
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The need to identify protein or peptide biomarkers via readily available biological samples like serum, plasma, or cerebrospinal fluid is often hindered by a few particular proteins present at relatively high concentrations. The ability to remove these proteins specifically, reproducibly, and with high selectivity is increasingly important in proteomic studies, and success in this procedure is leading to an ever-increasing list of lower abundant proteins being identified in these biological fluids. The current work addresses some of the potential problems in depleting proteins in typical biomarker studies, including nonspecific binding during depletion procedures and whether low molecular weight (LMW) species bind to the column in a so-called "sponge" effect caused by the ability of albumin or other high-abundant proteins to bind peptides or protein fragments. LC-MS/MS methods were applied to the comparative analysis of an IgG-based immunodepletion method and a Cibacron blue (CB)-dye-based method, for specificity of removing targeted proteins (binding fraction), as well as for assessing efficiency of target removal. This analysis was extended to examine the effects of repeated use of materials (cycles of binding and elution), in order to assess potential for carryover of one sample to the next. Capacity studies and efficiency of protein removal from the serum samples were followed for the IgG-based system using both immunochemical assays (ELISA) as well as LC-MS/MS methods. Additionally, the IgG-based system was further characterized for the removal of LMW polypeptides by nonspecific binding. We conclude that the IgG-based system provided effective removal of targeted proteins, with minimal carryover, high longevity, and minimal nonspecific binding. Significant differences are noted between the depletion techniques employed, and this should. be considered based on the expectations set during experimental design.
引用
收藏
页码:3304 / 3313
页数:10
相关论文
共 20 条
[1]  
Bailey J, 2003, GENET ENG NEWS, V23, P32
[2]   Comparison of different depletion strategies for improved resolution in proteomic analysis of human serum samples [J].
Björhall, K ;
Miliotis, T ;
Davidsson, P .
PROTEOMICS, 2005, 5 (01) :307-317
[3]   The proteomics bottleneck: strategies for preliminary validation of potential biomarkers and drug targets [J].
Bodovitz, S ;
Joos, T .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (01) :4-7
[4]   Proteomic analysis of human serum by two-dimensional differential gel electrophoresis after depletion of high-abundant proteins [J].
Chromy, BA ;
Gonzales, AD ;
Perkins, J ;
Choi, MW ;
Corzett, MH ;
Chang, BC ;
Corzett, CH ;
McCutchen-Maloney, SL .
JOURNAL OF PROTEOME RESEARCH, 2004, 3 (06) :1120-1127
[5]  
ECHAN LA, 2005, PROTEOMICS, V5, DOI DOI 10.1002/PMIC.200400518
[6]  
HENRY JB, 1996, CLIN DIAGNOSIS MANAG, P237
[7]  
Hinerfeld Douglas, 2004, J Biomol Tech, V15, P184
[8]   Biomarker discovery and validation:: technologies and integrative approaches [J].
Ilyin, SE ;
Belkowski, SM ;
Plata-Salamán, CR .
TRENDS IN BIOTECHNOLOGY, 2004, 22 (08) :411-416
[9]   Mining the human cerebrospinal fluid proteome by immunodepletion and shotgun mass spectrometry [J].
Maccarrone, G ;
Milfay, D ;
Birg, I ;
Rosenhagen, M ;
Holsboer, F ;
Grimm, R ;
Bailey, J ;
Zolotarjova, N ;
Turck, CW .
ELECTROPHORESIS, 2004, 25 (14) :2402-2412
[10]  
MARTOSELLA JD, 2005, IN PRESS J PROTEOME