Mouthpiece diameter affects deposition efficiency in cast models of the human oral airways

被引:46
作者
Lin, TC [1 ]
Breysse, PN [1 ]
Laube, BL [1 ]
Swift, DL [1 ]
机构
[1] Johns Hopkins Univ, Sch Hyg & Publ Hlth, Dept Environm Hlth Sci, Baltimore, MD USA
来源
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG | 2001年 / 14卷 / 03期
关键词
mouthpiece; deposition efficiency; oral-pharyngeal-laryngeal; therapeutic aerosol;
D O I
10.1089/089426801316970295
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
We examined the effect of altering mouthpiece diameter to 1.5, 2.0, and 2.7-cm on the deposition efficiency of inertial size particles (2, 4, and 8 mum) in adult human oral-pharyngeal-laryngeal (OPL) airway cast models at various inspiratory flow rates (30, 60, 90, and 120 L/min). Deposition efficiency of 2-mum particles was unaffected by changes in mouthpiece diameter at all flow rates. Deposition of 4-mum particles decreased significantly with the 2.0- and 2.7cm mouthpieces compared to the 1.5 cm mouthpiece at 60, 90, and 120 L/min (p < 0.01). Deposition of 4-mum particles was significantly reduced with the 2.7-cm mouthpiece compared to the 2.0-cm mouthpiece at 90 and 120 L/min (p < 0.05). Deposition efficiency of 8 mum particles decreased significantly with the 2.0- and 2.7-cm mouthpieces compared to the 1.5-cm mouthpiece at 60 L/min (p < 0.05), and with the 2.7-cm mouthpiece compared to the 1.5-cm mouthpiece at 120 L/min (p < 0.05). These results suggest that the effect of mouthpiece diameter varies with particle size, with 2- and 8-mum particles least affected. However, our findings may have important implications for improving the future design of mouthpieces of devices that deliver particles with 4-mum diameters and require inspiratory flow rates of greater than or equal to 60 L/min (i.e., DPIs) for adequate drug delivery.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 15 条
[1]   EXPERIMENTAL MEASUREMENTS AND EMPIRICAL MODELING OF THE REGIONAL DEPOSITION OF INHALED PARTICLES IN HUMANS [J].
CHAN, TL ;
LIPPMANN, M .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1980, 41 (06) :399-408
[2]   PARTITIONING OF RESPIRATORY FLOW RESISTANCE IN MAN [J].
FERRIS, BG ;
MEAD, J ;
OPIE, LH .
JOURNAL OF APPLIED PHYSIOLOGY, 1964, 19 (04) :653-&
[3]  
Fuchs N., 1966, AEROSOL SCI, P1
[4]   DELIVERY CHARACTERISTICS OF ALBUTEROL POWDER AEROSOL BY ROTAHALER [J].
KIM, CS ;
GARCIA, L .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (03) :199-211
[5]   EFFECT OF PARTICLE SIZE ON REGIONAL DEPOSITION OF INHALED AEROSOLS IN HUMAN RESPIRATORY TRACT [J].
LIPPMANN, M ;
ALBERT, RE .
AMERICAN INDUSTRIAL HYGIENE ASSOCIATION JOURNAL, 1969, 30 (03) :257-&
[6]   DO PARTICLE-SIZE AND AIRWAY-OBSTRUCTION AFFECT THE DEPOSITION OF PRESSURIZED INHALATION AEROSOLS [J].
NEWMAN, SP ;
KILLIP, M ;
PAVIA, D ;
MOREN, F ;
CLARKE, SW .
THORAX, 1983, 38 (03) :233-233
[7]   AEROSOL DEPOSITION CONSIDERATIONS IN INHALATION-THERAPY [J].
NEWMAN, SP .
CHEST, 1985, 88 (02) :S152-S160
[8]  
*NIOSH, 1983, ALT DI 2 ETH PTH RES
[9]   HOW TO USE A ROTAHALER [J].
PEDERSEN, S .
ARCHIVES OF DISEASE IN CHILDHOOD, 1986, 61 (01) :11-14
[10]  
Roberson J. A., 1980, Engineering Fluid Mechanics, V2nd