A comparison of micromanometric and standard manometric techniques for recording of oesophageal motility

被引:23
作者
Chen, WH
Omari, TI [1 ]
Holloway, RH
Checklin, H
Dent, J
机构
[1] Womens & Childrens Hosp, Gastroenterol Unit, N Adelaide, SA 5006, Australia
[2] Natl Taiwan Univ Hosp, Dept Internal Med, Div Gastroenterol, Taipei 100, Taiwan
[3] Royal Adelaide Hosp, Dept Gastrointestinal Med, Adelaide, SA 5000, Australia
关键词
fidelity; manometry; methods; micromanometry; oesophagus; rise rate;
D O I
10.1046/j.1365-2982.1998.00103.x
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Perfused micromanometric assemblies with an outer diameter of 2 mm or less have been developed for use in premature infants and small laboratory animals. Such assemblies offer advantages with regard to subject comfort and low perfusion rates that make them attractive for use in adults. The aim of this study was to investigate the recording fidelity of micromanometric assemblies in the measurement of oesophageal peristalsis in adults. Two micromanometric assemblies with an outer diameter of 1.8-2.0 mm and a length suitable for use in adults (265 cm), and containing micromanometric lumina of 0.28-0.35 mm i.d. and a standard lumen of 0.60. 75 mm i.d. were evaluated. Each assembly was tested by measurement of pressure rise rate in response to sudden occlusion, and in vivo during oesophageal peristalsis by simultaneous comparison with an intraluminal strain gauge. At perfusion rates of 0.01-0.15 mt min(-1) microlumina achieved pressure rise rates of 21-430 mmHg sec(-1) that were comparable to 37-390 mmHg sec(-1) for the standard lumina perfused at 0.25-0.6 mi. min(-1). During oesophageal peristalsis, micromanometric lumina recorded the occurrence and timing of all pressure waves accurately when compared with standard lumina and the microtransducer. However, microlumina under-recorded pressure wave amplitude to varying degrees dependent upon perfusion rate although the performance of microlumina could be improved to that of the standard lumen by shortening their length to 70 cm. Micromanometric assemblies are suitable for recording oesophageal peristalsis in adults although there is some impairment of absolute manometric fidelity. Fidelity can be improved by minimizing total assembly length.
引用
收藏
页码:253 / 262
页数:10
相关论文
共 11 条
  • [1] Andrews JM, 1997, GASTROENTEROLOGY, V112, pA692
  • [2] ARNDORFER RC, 1977, GASTROENTEROLOGY, V73, P23
  • [3] RESPONSES OF FERRET LOWER ESOPHAGEAL SPHINCTER TO 5-HYDROXYTRYPTAMINE - PATHWAYS AND RECEPTOR SUBTYPES
    BLACKSHAW, LA
    NISYRIOS, V
    DENT, J
    [J]. AMERICAN JOURNAL OF PHYSIOLOGY-GASTROINTESTINAL AND LIVER PHYSIOLOGY, 1995, 268 (06): : G1004 - G1011
  • [4] CLOUSE RE, 1997, GASTROENTEROLOGY, V112, pA420
  • [5] EFFECT OF PERISTALTIC DYSFUNCTION ON ESOPHAGEAL VOLUME CLEARANCE
    KAHRILAS, PJ
    DODDS, WJ
    HOGAN, WJ
    [J]. GASTROENTEROLOGY, 1988, 94 (01) : 73 - 80
  • [6] EFFECT OF MANOMETRIC ASSEMBLY DIAMETER ON INTRALUMINAL ESOPHAGEAL PRESSURE RECORDING
    LYDON, SB
    DODDS, WJ
    HOGAN, WJ
    ARNDORFER, RC
    [J]. AMERICAN JOURNAL OF DIGESTIVE DISEASES, 1975, 20 (10): : 968 - 970
  • [7] Intraluminal micromanometry: An evaluation of the dynamic performance of micro-extrusions and sleeve sensors
    Omari, T
    Bakewell, M
    Fraser, R
    Malbert, C
    Davidson, G
    Dent, J
    [J]. NEUROGASTROENTEROLOGY AND MOTILITY, 1996, 8 (03) : 241 - 245
  • [8] ESOPHAGEAL BODY AND LOWER ESOPHAGEAL SPHINCTER FUNCTION IN HEALTHY PREMATURE-INFANTS
    OMARI, TI
    MIKI, K
    FRASER, R
    DAVIDSON, G
    HASLAM, R
    GOLDSWORTHY, W
    BAKEWELL, M
    KAWAHARA, H
    DENT, J
    [J]. GASTROENTEROLOGY, 1995, 109 (06) : 1757 - 1764
  • [9] ESOPHAGEAL MANOMETRY IN 95 HEALTHY ADULT VOLUNTEERS - VARIABILITY OF PRESSURES WITH AGE AND FREQUENCY OF ABNORMAL CONTRACTIONS
    RICHTER, JE
    WU, WC
    JOHNS, DN
    BLACKWELL, JN
    NELSON, JL
    CASTELL, JA
    CASTELL, DO
    [J]. DIGESTIVE DISEASES AND SCIENCES, 1987, 32 (06) : 583 - 592
  • [10] RICHTER JE, 1987, J LAB CLIN MED, V109, P217