Doppler ultrasound evaluation of ductus venosus blood flow during acute hypoxemia in fetal lambs

被引:59
作者
Tchirikov, M [1 ]
Eisermann, K [1 ]
Rybakowski, C [1 ]
Schroder, HJ [1 ]
机构
[1] Univ Hamburg, Frauenklin, Abt Expt Med, Dept Expt Med, D-20246 Hamburg, Germany
关键词
ductus venosus blood flow; hypoxemia; ultrasound; Doppler; fetal lambs;
D O I
10.1046/j.1469-0705.1998.11060426.x
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
It has been demonstrated with invasive techniques in fetal lambs that the ratio of ductus venosus to umbilical vein blood flow rate (DV/UV ratio) increases during hypoxemia and infusion of catecholamines. Recently it was found in human fetuses using pulsed wave Doppler ultrasound equipment that the DV/UV ratio in fetuses with intrauterine growth restriction Was significantly increased. The aim of the present study was to show in fetal lambs whether routine Doppler ultrasound devices were capable of determining the DV/UV ratio With sufficient reliability The experiments were performed on seven near-term instrumented fetal lambs using pulsed wave Doppler ultrasound to measure flow rates (derived, in milliliters per min, from the intensity-weighted mean velocity (V-mean) and the vessel's cross-sectional area) in the ductus venosus and intra-abdominal umbilical vein. Fetal hypoxemia was induced by administering a low-oxygen gas to the ewe (5-7% oxygen, 2% carbon dioxide). Fetal arterial pO(2) and heart rate decreased significantly during maternal hypoxia. The proportion of umbilical venous return passing through the ductus venosus in controls was 36 +/- 5% (mean +/- SD). This increased to 53 +/- 6% (p < 0.001) because the umbilical venous blood flow fell during late hypoxemia when the heart rare had decreased by 20%. Severe hypoxemia tended to reduce the mean velocity (V-mean) and the minimum velocity (V-min) (based on the maximum velocity envelope curve) in the ductus venosus, descending aorta and inferior vena cava. The pulsatility index of the umbilical artery significantly increased at the end of hypoxemia. We conclude that determination of the proportion of umbilical vein blood pow entering the ductus venosus by Doppler ultrasound in a clinical setting may contribute to the detection and evaluation of fetal distress.
引用
收藏
页码:426 / 431
页数:6
相关论文
共 21 条
[1]   ASSESSMENT OF THE FETAL POT CHANGES BY CEREBRAL AND UMBILICAL DOPPLER ON LAMB FETUSES DURING ACUTE-HYPOXIA [J].
ARBEILLE, P ;
MAULIK, D ;
FIGNON, A ;
STALE, H ;
BERSON, M ;
BODARD, S ;
LOCATELLI, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1995, 21 (07) :861-870
[2]  
BEHRMANN RE, 1970, AM J OBSTET GYNECOL, V103, P956
[3]  
BURNS PN, 1987, REPROD PERINATAL MED, P47
[4]   PLASMA-CATECHOLAMINES DURING HYPOXEMIA IN FETAL LAMB [J].
COHEN, WR ;
PIASECKI, GJ ;
JACKSON, BT .
AMERICAN JOURNAL OF PHYSIOLOGY, 1982, 243 (05) :R520-R525
[5]   PREFERENTIAL STREAMING OF DUCTUS VENOSUS BLOOD TO THE BRAIN AND HEART IN FETAL LAMBS [J].
EDELSTONE, DI ;
RUDOLPH, AM .
AMERICAN JOURNAL OF PHYSIOLOGY, 1979, 237 (06) :H724-H729
[6]  
HUNEKE B, 1992, J MATERN-FETAL INVES, V2, P225
[7]  
JENSEN A, 1993, FETUS NEONATE PHYSL, P23
[8]  
JONES CT, 1983, J DEV PHYSIOL, V5, P77
[9]   DUCTUS VENOSUS BLOOD VELOCITY AND THE UMBILICAL CIRCULATION IN THE SERIOUSLY GROWTH-RETARDED FETUS [J].
KISERUD, T ;
EIKNES, SH ;
BLAAS, HG ;
HELLEVIK, LR ;
SIMENSEN, B .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 1994, 4 (02) :109-114
[10]   CATECHOLAMINE METABOLITES IN AMNIOTIC-FLUID AS INDICATORS OF INTRAUTERINE STRESS [J].
LAGERCRANTZ, H ;
SJOQUIST, B ;
BREMME, K ;
LUNELL, NO ;
SOMELL, C .
AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1980, 136 (08) :1067-1070