Small-vessel radiography in situ with monochromatic synchrotron radiation

被引:135
作者
Mori, H
Hyodo, K
Tanaka, E
UddinMohammed, M
Yamakawa, A
Shinozaki, Y
Nakazawa, H
Tanaka, Y
Sekka, T
Iwata, Y
Handa, S
Umetani, K
Ueki, H
Yokoyama, T
Tanioka, K
Kubota, M
Hosaka, H
Ishikawa, N
Ando, M
机构
[1] TOKAI UNIV,SCH MED,DEPT SURG 2,ISEHARA,KANAGAWA 25911,JAPAN
[2] TOKAI UNIV,SCH MED,DEPT RADIOL,ISEHARA,KANAGAWA 25911,JAPAN
[3] TOKAI UNIV,SCH MED,DEPT INTERNAL MED 1,ISEHARA,KANAGAWA 25911,JAPAN
[4] NATL LAB HIGH ENERGY PHYS,TSUKUBA,IBARAKI 305,JAPAN
[5] HITACHI LTD,CENT RES LAB,TOKYO,JAPAN
[6] NIPPON HOSO KYOKAI SCI & TECH RES LABS,TOKYO,JAPAN
[7] NIHON KOHDEN,TOKYO,JAPAN
关键词
angiography; technology; cerebral angiography; coronary angiography; intestines; radiography; pancreas; synchrotron;
D O I
10.1148/radiology.201.1.8816540
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate the usefulness of a radiographic system with monochromatic synchrotron radiation to depict small vessels and peripheral secretory ducts. MATERIALS AND METHODS: Radiography of various organs was tested in 14 anesthetized dogs and pancreatography was performed in an excised human pancreas by using the following system: monochromatic synchrotron radiation with an energy level just above the k absorption edge of iodine as an x-ray source and a high-definition TV system with a high-light-sensitivity image pick-up tube camera coupled with a fluorescent screen as a detector. RESULTS: This system allowed depiction of small vessels (diameter <50-100 mu m) of the heart (penetrating transmural artery), brain (perforating arteries that arise directly in the circle of Willis), and intestinal organs (vasa recta and their submucosal communications) and of small branches (down to the fifth order) of the pancreatic duct. CONCLUSION: The synchrotron radiation system may be useful for evaluating microcirculatory disorders and early-stage malignant tumors in various human organs.
引用
收藏
页码:173 / 177
页数:5
相关论文
共 15 条
[1]   MICROVASCULAR ANGINA AS A CAUSE OF CHEST PAIN WITH ANGIOGRAPHICALLY NORMAL CORONARY-ARTERIES [J].
CANNON, RO ;
EPSTEIN, SE .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 61 (15) :1338-1343
[2]  
CUBBILA AL, 1984, ATLAS TUMOR PATHOL 2, P36
[3]  
*DIV RES RES NIH, 1985, NIH PUBL, V8623
[4]   LACUNAR STROKES AND INFARCTS - A REVIEW [J].
FISHER, CM .
NEUROLOGY, 1982, 32 (08) :871-876
[5]   PRESSURE-FLOW RELATIONS IN CORONARY CIRCULATION [J].
HOFFMAN, JIE ;
SPAAN, JAE .
PHYSIOLOGICAL REVIEWS, 1990, 70 (02) :331-390
[6]  
HYODO K, 1991, SYNCHROTRON RAD HDB, P55
[7]   CHARGE-COUPLED DEVICE DETECTOR - PERFORMANCE CONSIDERATIONS AND POTENTIAL FOR SMALL-FIELD MAMMOGRAPHIC IMAGING APPLICATIONS [J].
KARELLAS, A ;
HARRIS, LJ ;
LIU, H ;
DAVIS, MA ;
DORSI, CJ .
MEDICAL PHYSICS, 1992, 19 (04) :1015-1023
[8]  
LEIKOF W, 1967, NEW ENGL J MED, V276, P1063
[9]   METHODS TO CALCULATE THE LENS EFFICIENCY IN OPTICALLY COUPLED CCD X-RAY-IMAGING SYSTEMS [J].
LIU, H ;
KARELLAS, A ;
HARRIS, LJ ;
DORSI, CJ .
MEDICAL PHYSICS, 1994, 21 (07) :1193-1195
[10]   VISUALIZATION OF PENETRATING TRANSMURAL ARTERIES IN-SITU BY MONOCHROMATIC SYNCHROTRON-RADIATION [J].
MORI, H ;
HYODO, K ;
TOBITA, K ;
CHUJO, M ;
SHINOZAKI, Y ;
SUGISHITA, Y ;
ANDO, M .
CIRCULATION, 1994, 89 (02) :863-871