Modular design of permanent-magnet generators for wind turbines

被引:74
作者
Spooner, E [1 ]
Williamson, AC [1 ]
Catto, G [1 ]
机构
[1] UNIV MANCHESTER,INST SCI & TECHNOL,DEPT ELECT ENGN & ELECT,MANCHESTER M60 1QD,LANCS,ENGLAND
来源
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS | 1996年 / 143卷 / 05期
关键词
wind turbines; permanent magnet generators; reactance; efficiency;
D O I
10.1049/ip-epa:19960434
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Radial-field, multipole, permanent-magnet, synchronous machines may be used as direct-coupled generators for large grid-connected wind turbines. Power ratings from below 100 kW to more than 1 MW and pole numbers of 100 to 300 may be required. Modular construction reduces the detail design effort, and the number of drawings and tools needed. Module designs are presented which can be used for a wide range of machine designs, The rotor modules use standard ferrite magnet blocks. The stator modules are simple E cores each carrying a single rectangular coil, The arrangement eases assembly of the magnetised parts and creates a machine with low reactances and high efficiency.
引用
收藏
页码:388 / 395
页数:8
相关论文
共 10 条
[1]  
Caricchi F., 1992, Proceedings. International Conference on Electrical Machines, P761
[2]  
DELEROI W, 1992, SPEEDAM S POS IT MAY, P71
[3]  
FUCHS EF, 1992, AM WIND EN ASS C SEA
[4]  
GRUBB MJ, 1991, IEE PROC-C, V138, P149, DOI 10.1049/ip-c.1991.0018
[5]   WIND ENERGY - AN OPTION FOR THE UK [J].
HALLIDAY, JA .
IEE PROCEEDINGS-A-SCIENCE MEASUREMENT AND TECHNOLOGY, 1993, 140 (01) :53-62
[6]  
LAMPOLA P, 1995, P IEEE POW C STOCKH, P211
[7]   ROLE AND OBJECTIVES OF CONTROL FOR WIND TURBINES [J].
LEITHEAD, WE ;
DELASALLE, S ;
REARDON, D .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1991, 138 (02) :135-148
[8]  
SPOONER E, Patent No. 2278738
[9]  
SPOONER E, 1996, IEE P B, V143, P1996
[10]   MODELING AND OUTPUT POWER OPTIMIZATION OF A WIND TURBINE DRIVEN DOUBLE OUTPUT INDUCTION GENERATOR [J].
UCTUG, MY ;
ESKANDARZADEH, I ;
INCE, H .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1994, 141 (02) :33-38