Hickman catheter-related infections in neutropenic patients:: Insertion in the operating theater versus insertion in the radiology suite

被引:46
作者
Nouwen, JL
Wielenga, JJ
van Overhagen, H
Laméris, JS
Kluytmans, JAJW
Behrendt, MD
Hop, WCJ
Verbrugh, HA
de Marie, S
机构
[1] Erasmus Univ, Med Ctr, Dept Med Microbiol & Infect Dis, NL-3015 GD Rotterdam, Netherlands
[2] Erasmus Univ, Med Ctr, Dept Hematol, NL-3015 GD Rotterdam, Netherlands
[3] Erasmus Univ, Med Ctr, Dept Radiol, NL-3015 GD Rotterdam, Netherlands
[4] Erasmus Univ, Med Ctr, Dept Epidemiol & Biostat, NL-3015 GD Rotterdam, Netherlands
关键词
D O I
10.1200/JCO.1999.17.4.1304
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: To determine the influence of microbial air quality during Hickman catheter insertion in the operating theater versus insertion in the radiology suite on the incidence of catheter-related infections (CRIs). Patients and Methods: Hemato-oncologic patients with prolonged neutropenia on antimicrobial prophylaxis were entered onto the study. Catheters were inserted by experienced radiologists under sonographic and fluoroscopic guidance. Results: Forty-eight Hickman catheters in 39 patients were inserted (23 in the operating theater, 25 in the radiology suite). CRIs were seen in 16 catheters (33%; six per 1,000 catheter days; eight in each group). Local infections were found in nine catheters (22%; six in the operating theater v three in the radiology suite; not significant [NS]), catheter-related bacteremia was found in 10(29%; three in the operating theater v seven in the radiology suite; NS), Coagulase-negative staphylococci (CoNS) caused all CRIs, Despite early vancomycin therapy, 11 (69%; four in the operating room group v seven in the radiology suite group; NS) of the catheters with CRIs had to be removed prematurely At 90 days after insertion, catheter survival was 78% and 60% (NS) for the operating room and radiology suite, respectively. Multivariate analysis showed that neutropenia increased the CRI risk 20-fold (P = .004) and was strongly related to premature catheter removal owing to infection (relative risk = 11.9; P = .009). Neutropenia on the day of insertion was also significantly correlated with CRI (P = .04) and premature catheter removal owing to infection (P = .03). Serial cultures of blood, exit site, and catheter hub did not predict the development of CRI. Conclusion: The high incidence of Hickman CRI caused by CoNS was not associated with insertion location (operating theater v radiology suite). Neutropenia, including neutropenia on the day of insertion, was a significant risk factor for CRI and infection-related catheter removal.
引用
收藏
页码:1304 / 1311
页数:8
相关论文
共 49 条
[1]   A PROSPECTIVE-STUDY OF PROLONGED CENTRAL VENOUS ACCESS IN LEUKEMIA [J].
ABRAHM, JL ;
MULLEN, JL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1982, 248 (21) :2868-2873
[3]  
*AM SOC MICR, 1992, CLIN MICR PROC HDB
[4]   Infectious complications of radiologically inserted Hickman catheters in patients with hematologic disorders [J].
Bakker, J ;
van Overhagen, H ;
Wielenga, J ;
de Marie, S ;
Nouwen, J ;
de Ridder, MAJ ;
Lameris, JS .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) :116-121
[5]   RISK OF INFECTION ASSOCIATED WITH THE USE OF BROVIAC AND HICKMAN CATHETERS [J].
BEGALA, JE ;
MAHER, K ;
CHERRY, JD .
AMERICAN JOURNAL OF INFECTION CONTROL, 1982, 10 (01) :17-23
[6]  
BLACKLOCK HA, 1980, LANCET, V1, P993
[7]  
CLAESSEN KA, 1990, NETH J SURG, V42, P47
[8]   INFECTIOUS COMPLICATIONS OF INDWELLING LONG-TERM CENTRAL VENOUS CATHETERS [J].
CLARKE, DE ;
RAFFIN, TA .
CHEST, 1990, 97 (04) :966-972
[9]   INSERTION OF HICKMAN CENTRAL VENOUS CATHETERS BY USING ANGIOGRAPHIC TECHNIQUES IN PATIENTS WITH HEMATOLOGIC DISORDERS [J].
COCKBURN, JF ;
EYNON, CA ;
VIRJI, N ;
JACKSON, JE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (01) :121-124
[10]  
COX DR, 1972, J R STAT SOC B, V34, P187