Cefuroxime selective electrodes for batch and FIA determinations in pharmaceutical preparations

被引:18
作者
Lima, JLFC [1 ]
Montenegro, MCBSM [1 ]
Sales, MGF [1 ]
机构
[1] CEQUP, Dept Quim Fis, Fac Farm, P-4050 Porto, Portugal
关键词
cefuroxime; pharmaceutical preparations; ion-selective electrodes; potentiometry; cephalosporin; FIA;
D O I
10.1016/S0731-7085(98)00162-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Different cefuroxime selective electrodes, without internal reference solution and comprising PVC membranes, were constructed and evaluated. Membranes were prepared with cefuroxime tetraoctylammonium (A) or cefuroxime bis(triphenylphosphoranylidene)ammonium (B) as ion-exchanger, 2-nitrophenyl octyl ether (X) or bis(2-ethyl hexyl)sebacate (Y) as plasticizing mediator solvent and 4-tert-otcylphenol (TOP) as additive. From the comparative evaluation of the described electrodes, membranes comprising 2-nitrophenyl octyl ether, cefuroxime tetraoctylammonium and 4-tert-otcylphenol presented better working characteristics. For these electrodes (type XA-TOP), with a lifetime > 5 months, a lower limit of linear range of 2.8 x 10(-4) M, a practical detection limit of 1.3 x 10-4 M, a reproducibility of similar to +/- 0.6 mV day(-1) and a slope of - 50.4 mV decade(-1), under H3PO4/NaH2PO4 solutions (pH 3.5; I = 0.1 M), were found. The presence of the additive on the membranes was of crucial importance for the electrodes good characteristics. Interference from sulphate, chloride, nitrate, iodide, cefaclor, cefadroxil, cefazolin and cephradine, on the electrodes behaviour was evaluated. Only a slight interference from nitrate and iodide was recorded, being type XA-TOP electrodes the most selective units. Electrodes with a tubular configuration prepared with type XA-TOP membranes, aiming flow injection analysis, were also constructed. When these tubular potentiometric detectors were evaluated in a double-channel flow injection manifold, with 3.5 pH and 0.1 M ionic strength conditions, significantly better working characteristics than those of the corresponding conventional electrodes, namely higher slopes (-54.6 mV decade(-1)) and better reproducibilities (+/-0.2 mV day(-1)); were found. Both conventional and tubular type XA-TOP electrodes were used for injections analyses by batch and FIA, respectively, presenting low consumption of samples and reagents. Relative error deviations to the reference procedures < 3.0% were found. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:93 / 103
页数:11
相关论文
共 36 条
[1]   FIA TITRATIONS OF EPHEDRINE IN PHARMACEUTICAL FORMULATIONS WITH A PVC TETRAPHENYLBORATE TUBULAR ELECTRODE [J].
ALCADA, MNMP ;
LIMA, JLFC ;
MONTENEGRO, MCBSM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1995, 13 (4-5) :459-464
[2]   FLOW-THROUGH SANDWICH PVC MATRIX MEMBRANE-ELECTRODE FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
LIMA, JLFC ;
MACHADO, AASC ;
PAULIS, JM .
ANALYTICAL LETTERS PART A-CHEMICAL ANALYSIS, 1985, 18 (18) :2291-2303
[3]   FLOW-THROUGH TUBULAR PVC MATRIX MEMBRANE-ELECTRODE WITHOUT INNER REFERENCE SOLUTION FOR FLOW-INJECTION ANALYSIS [J].
ALEGRET, S ;
ALONSO, J ;
BARTROLI, J ;
PAULIS, JM ;
LIMA, JLFC ;
MACHADO, AASC .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :147-152
[4]  
ALEGRET S, 1987, QUIM ANAL, V6, P278
[5]   POLAROGRAPHIC-BEHAVIOR OF THE BETA-LACTAM ANTIBIOTIC CEFUROXIME AND STUDY OF THE REDUCTION-MECHANISM IN ACIDIC MEDIA [J].
BERNACCA, G ;
NUCCI, L ;
PERGOLA, F .
ELECTROANALYSIS, 1994, 6 (04) :327-332
[6]  
BUDAVARI S, 1989, INDEX MERCK ENCY CHE, P948
[7]   BENZYLPENICILLIN PVC MEMBRANE-ELECTRODE FOR THE DETERMINATION OF ANTIBIOTICS IN FORMULATIONS [J].
CAMPANELLA, L ;
MAZZEI, F ;
SBRILLI, R ;
TOMASSETTI, M .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (03) :299-305
[8]  
CAMPANELLA L, 1990, ANN CHIM-ROME, V80, P395
[9]   POLYMERIC MEMBRANE ELECTRODES FOR DRUG ANALYSIS [J].
CAMPANELLA, L ;
TOMASSETTI, M ;
MAZZEI, F ;
SBRILLI, R .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1988, 6 (6-8) :717-723
[10]  
COOMBER PA, 1982, ANALYST, V107, P1451, DOI 10.1039/an9820701451